Schneider Electric ATV1200A9401010

Schneider ATV1200A9401010 Altivar 1200, 786 kW, 940 kVA

MPN ATV1200A9401010
Active

Schneider Electric Altivar 1200 ATV1200A9401010 medium-voltage AC drive, 786 kW / 940 kVA, 48-pulse diode rectifier, 2970-3630 V supply, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV1200A9401010 specifications
ParameterValue
Input type48 pulse diode rectifier bridge
Protection typeGround fault protection: drive
Coil voltage220 V
Current65 A
IP ratingIP41 / IP31 / IP42
Temp storage max60 °C
Temp storage min-10 °C
Temp operating max50 °C
Temp operating min0 °C
Storage temperature-10...60 °C
Pollution degreePollution degree 2
Depth1600 mm (standard efficiency)
Width4260 mm (standard efficiency)
Height2670 mm standard efficiency
Operating positionVertical +/- 10 degree
Operating temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)

Product details

Medium-voltage drive, 48-pulse architecture

The ATV1200A9401010 is a Schneider Electric Altivar 1200 medium-voltage AC drive rated for 786 kW motor power at 940 kVA apparent power, supplied from a 2970-3630 V line. Its 48-pulse diode rectifier bridge input draws 65 A line current and delivers the harmonic profile needed to meet IEEE 519 without external filtering on most installations.

Physical footprint and enclosure

This drive ships as a floor-standing enclosure measuring 2670 mm high by 4260 mm wide by 1600 mm deep, with separate air flows for the power section and control compartment. Forced convection cooling moves 23100 m³/h of air at standard efficiency; the operating position is vertical within ±10 degrees.

Overload capability and isolation margins

Standard overload rating handles 1.2× rated current for 60 s and 1.5× for 3 s; the high-overload profile extends to 1.5× for 60 s and 1.85× for 3 s. Dielectric strength between earth and power terminals is 28 kV AC, with electrical isolation between power and control circuits per EN/IEC 61800-5-1.

System composition and supply requirements

The drive comprises two plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, a human-machine interface, and 24 power cells. Control supply is 220 V AC at 3 kVA (external), with an optional 220 V AC/DC external supply; the internal cooling fan supply is 380 V AC.

Compliance and environmental limits

CE marked and designed to EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. Pollution degree 2 per the latter standard. Operating altitude range is 1000-2000 m with 0.6 % current derating per 100 m above 1000 m; relative humidity 0-90 % standard, 0-95 % optional.

Sourced through authorized distribution channels; quoted to order against the BOM quantity with volume pricing and lead time confirmed at RFQ.

MPN