Schneider Electric ATV1200A9406666 — AC Drive (VFD) 480V

Schneider ATV1200A9406666 Altivar 1200 VFD, 940 kVA, 786 kW

MPNATV1200A9406666
Active

Schneider Electric Altivar 1200 ATV1200A9406666 medium-voltage AC drive, 940 kVA, 786 kW, 2970...3630 V supply, 36-pulse diode rectifier, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A9406666 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A9406666 — Power & Output
ParameterValue
Motor power (kW)786 kW
Continuous output current82 A (standard overload) 66 A (high overload)
Max. transient current99 A for 60 s
Apparent power940 kVA

Input / Supply

ATV1200A9406666 — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current100 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A9406666 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesVector control with sensor, optional Sensorless flux vector control Voltage/frequency ratio (V/f) Closed-loop control with encoder
Synchronous motor control modesVoltage/frequency ratio (V/f) Closed-loop control with encoder

Protection & EMC

ATV1200A9406666 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A9406666 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP41 IP42 IP31
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A9406666 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A9406666 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A9406666 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

Power stage and motor sizing

The ATV1200A9406666: Rated for 940 kVA apparent power and 786 kW motor output — this is a medium-voltage drive for large asynchronous motors, not a 480 V unit. The 36-pulse diode rectifier front end cleans up line harmonics well below IEEE 519 thresholds without external filtering. Supply voltage range is 2970...3630 V. Output voltage follows the supply, so the motor sees the full line voltage minus rectifier drop. The 36-pulse topology means the transformer feeding it needs 6 secondary windings phase-shifted 10 degrees apart.

Overload duty and thermal management

Standard overload profile: 1.2× In for 60 s, 1.5× In for 3 s. High overload profile steps up to 1.5× In for 60 s and 1.85× In for 3 s. The high overload setting is the one to budget for if the driven load has breakaway torque demands — a crusher or centrifuge, not a centrifugal pump. Forced convection cooling moves 13,200 m³/h in the standard-efficiency build, 19,800 m³/h in the high-efficiency variant. That volume of air needs ducting out of the room — the drive rejects heat at the transformer and cell level, not through a backplane heat sink. Acoustic noise hits 80 dB, so plan for ear protection in the vicinity during commissioning.

Physical footprint and site prep

Floor-standing enclosure with separate air flows. Standard-efficiency footprint: 3060 mm wide × 1400 mm deep × 2520 mm high. High-efficiency build: 3360 mm wide × 1500 mm deep × 2670 mm high. The width difference matters for cable entry planning — the high-efficiency cabinet has more cell bays and wider buswork. Electrical connection via M10 screw-type bar terminals, clamping capacity 6 × 40 mm² per phase. Entry from top or bottom. The 31.5 kA prospective short-circuit current for 150 ms means the upstream protection must coordinate — a 36-pulse transformer typically has higher impedance than a 6-pulse unit, so the fault let-through is lower, but the SCCR rating of the drive itself needs to match the installation.

System composition and control interface

The drive ships as a complete assembly: 2 plinths, phase-shifting transformer, medium-voltage arrestors, cooling fans, HMI, and 18 power cells. The 18 cells means 6 cells per phase in a 36-pulse configuration — each cell is a low-voltage inverter stage fed from its own transformer secondary. If a cell faults, the drive can typically continue at reduced voltage with the remaining cells. Control interface: 4 software-configurable analogue inputs (0...20 mA / 4...20 mA, 250 Ohm impedance), 1 analogue output, 6 discrete inputs standard with optional expansion to 10. The control supply is 220 V AC at 3 kVA — this powers the control electronics independently of the main power bus, so the HMI and I/O stay live even with the main breaker open.

Compliance and standards coverage

CE marked. Standards compliance includes EN/IEC 60204-11 (safety of machinery), EN/IEC 61800-3 (EMC for drive systems), EN/IEC 61800-4 (voltage disturbances), and EN/IEC 61800-5-1 (electrical safety). Pollution degree 2 per EN/IEC 61800-5-1 — the enclosure is rated for a clean industrial environment, not cement dust or foundry grit. Dielectric strength tested at 20 kV AC between earth and power terminals. Electrical isolation between power and control means the 24 V I/O loop is galvanically separated from the 3 kV bus — no ground-loop coupling through the control cable shield.

MPN
ATV1200A9406666