Skip to main content
Schneider Electric ATV1200A97506666 — AC Drive (VFD) 480V

Schneider ATV1200A97506666 AC Drive, 8151 kW, 2970-3630 V

MPNATV1200A97506666
Active

Schneider Electric Altivar 1200 ATV1200A97506666 AC drive, 8151 kW motor power, 2970-3630 V supply, 36-pulse diode rectifier, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV1200A97506666 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV1200
Product range / familyAltivar 1200

Power & Output

ATV1200A97506666 — Power & Output
ParameterValue
Motor power (kW)8151 kW
Continuous output current850 A (standard overload) 680 A (high overload)
Max. transient current1020 A for 60 s
Apparent power9750 kVA

Input / Supply

ATV1200A97506666 — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current850 A
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for control at 220 V AC, 3 kVA Internal supply for cooling fan at 380 V AC External supply for control at 220 V AC/DC (optional) External supply for cooling fan at 380 V AC (optional)

Control & Performance

ATV1200A97506666 — Control & Performance
ParameterValue
Output frequency range0.5...120 Hz voltage/frequency ratio (V/f) 0.5...70 Hz vector control with/without speed feedback
Asynchronous motor control modesSensorless flux vector control Voltage/frequency ratio (V/f) Vector control with sensor, optional Closed-loop control with encoder
Synchronous motor control modesClosed-loop control with encoder Voltage/frequency ratio (V/f)

Protection & EMC

ATV1200A97506666 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated
Protection functionsGround fault protection: drive
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV1200A97506666 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP41 IP31 IP42
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure with separate air flows

Environmental

ATV1200A97506666 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C (with current derating of 2 % per °C)
Operating altitude1000...2000 m with current derating 0.6 % per 100 m
Relative humidity0...90 % 0...95 % optional
Storage / transport temperature-10...60 °C
Pollution degree2 conforming to EN/IEC 61800-5-1
Vibration resistance4.9 m/s² (f= 10...50 Hz)

Approvals

ATV1200A97506666 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN/IEC 60204-11 EN/IEC 60529 EN/IEC 61800-3 EN/IEC 61800-4 EN/IEC 61800-5-1

Communication

ATV1200A97506666 — Communication
ParameterValue
Communication protocolsHuman machine interface: Modbus with 2-wire RS485(1) - SUB-D 9 Human machine interface: Modbus TCP with (1) - RJ45 Human machine interface: EtherNet/IP with (1) - RJ45 Human machine interface: Profibus with (1) - SUB-D 9 Human machine interface: DeviceNet with (1) - SUB-D 9

Product details

Floor-standing medium-voltage drive, 8151 kW

The ATV1200A97506666 is a Schneider Electric Altivar 1200 series AC drive rated for 8151 kW motor power at a supply voltage of 2970-3630 V. It uses a 36-pulse diode rectifier bridge input, which reduces line-side harmonics compared to 6- or 12-pulse topologies — relevant for installations where IEEE 519 compliance or utility-imposed THD limits apply. The drive is assembled in a floor-standing enclosure with separate air flows for the power section and control compartment. The enclosure is grey (RAL 7032) and measures 9770 mm wide by 3340 mm high by 1700 mm deep — this is a large-format drive that requires a dedicated equipment room or outdoor shelter with crane access for positioning.

36-pulse topology and overload profile

The 36-pulse diode rectifier bridge draws a line current of 850 A and delivers an apparent power rating of 9750 kVA. The prospective line short-circuit current withstand is 31.5 kA for 150 ms — this sets the upstream fault-clearing requirement for the supply transformer and switchgear coordination study. Overload capability is specified in two duty classes: standard overload allows 1.2× In for 60 s or 1.5× In for 3 s; high overload allows 1.5× In for 60 s or 1.85× In for 3 s. The high-overload profile is typically selected for applications with intermittent peak torque demands, such as crushers or extruders, while standard overload suits centrifugal pumps and fans. The drive includes integrated EMC filtering and provides electrical isolation between the power and control circuits. Dielectric strength is rated at 20 kV AC between earth and power terminals — a figure that confirms the drive is designed for ungrounded or high-resistance-grounded medium-voltage distribution systems.

Product composition and control interface

The ATV1200A97506666 ships as a complete assembly comprising two plinths, a phase-shifting transformer, medium-voltage arrestors, cooling fans, a human-machine interface, and 18 power cells. The phase-shifting transformer is the key component that enables the 36-pulse rectification — each power cell receives a phase-shifted secondary winding, cancelling harmonics up to the 35th order. Control wiring connects to four software-configurable analogue inputs (0-20 mA or 4-20 mA, 24 V max, 250 Ohm impedance) and one analogue output of the same type. Discrete I/O includes six digital inputs standard, expandable to ten with an optional module. The control supply requires an external 220 V AC source at 3 kVA; the cooling fans draw 380 V AC from an internal supply. Power connections use M10 screw-type bars with a clamping capacity of 6 × 40 mm² per phase (/R, /S, L3/T), with cable entry from the top or bottom. The drive is designed for vertical installation within ±10° and requires 100,000 m³/h of cooling air at standard efficiency — this airflow demand must be factored into the room HVAC design.

Standards compliance and environmental limits

The drive carries CE marking and complies with EN/IEC 60204-11, EN/IEC 60529, EN/IEC 61800-3, EN/IEC 61800-4, and EN/IEC 61800-5-1. The pollution degree is 2 per EN/IEC 61800-5-1, and the overvoltage category is II — this means the drive is intended for installation in a clean, controlled environment (typically a dedicated electrical room) rather than directly on a production floor. Relative humidity range is 0-90% (0-95% optional), and the operating position is vertical within ±10°. The noise level is 80 dB — hearing protection is required within the equipment room during operation.

Frequently asked questions

What is the motor power rating of the ATV1200A97506666?

The drive is rated for 8151 kW motor power at a supply voltage of 2970-3630 V. This is the continuous output capability at the drive terminals.

What input rectifier topology does the ATV1200A97506666 use?

It uses a 36-pulse diode rectifier bridge. This topology significantly reduces line-side harmonic distortion compared to 6- or 12-pulse drives, which is critical for meeting IEEE 519 or utility-imposed THD limits without external harmonic filters.

What overload capabilities does the ATV1200A97506666 offer?

Standard overload allows 1.2× In for 60 s or 1.5× In for 3 s. High overload allows 1.5× In for 60 s or 1.85× In for 3 s. The high-overload profile is suited for applications with intermittent peak torque demands like crushers or extruders.

MPN