Skip to main content
Schneider Electric ATV212HU40N4LCD — AC Drive (VFD) 480V

ATV212HU40N4LCD Altivar 212 4 kW VFD, 480 V, integrated C2 E

MPNATV212HU40N4LCD
Obsolete

Schneider Electric Altivar 212, ATV212HU40N4LCD, 4 kW / 5 hp variable speed drive, 380-480 V, integrated Class C2 EMC filter, IP20, 184 x 142 x 150 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ATV212HU40N4LCD — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV212
Product range / familyAltivar 212
ATV212HU40N4LCD — Power & Output
ParameterValue
Motor power (kW)4 kW
Continuous output current9.1 A at 380 V 9.1 A at 460 V
Max. transient current10 A for 60 s
Apparent power6.9 kVA at 380 V
ATV212HU40N4LCD — Input / Supply
ParameterValue
Rated supply voltage range380...480 V - 15...10 %
Input line current6.4 A at 480 V 8.1 A at 380 V
Network number of phases3 phases
ATV212HU40N4LCD — Control & Performance
ParameterValue
Output frequency range0.5...200 Hz
Asynchronous motor control modesVoltage/frequency ratio, 5 points Voltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Flux vector control without sensor, standard Voltage/frequency ratio, 2 points Voltage/frequency ratio - Energy Saving, quadratic U/f
ATV212HU40N4LCD — Protection & EMC
ParameterValue
Integrated EMC filter classClass C2 EMC filter integrated
Protection functionsOverheating protection: drive Thermal power stage: drive Short-circuit between motor phases: drive Input phase breaks: drive Overcurrent between output phases and earth: drive Overvoltages on the DC bus: drive Break on the control circuit: drive Against exceeding limit speed: drive Line supply overvoltage and undervoltage: drive Line supply undervoltage: drive Against input phase loss: drive Thermal protection: motor Motor phase break: motor With PTC probes: motor
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Prospective short-circuit current (Isc)5 kA
ATV212HU40N4LCD — Mechanical & Cooling
ParameterValue
IP degree of protectionIP20 on upper part without blanking plate on cover conforming to EN/IEC 61800-5-1 IP20 on upper part without blanking plate on cover conforming to EN/IEC 60529 IP21 conforming to EN/IEC 61800-5-1 IP21 conforming to EN/IEC 60529 IP41 on upper part conforming to EN/IEC 61800-5-1 IP41 on upper part conforming to EN/IEC 60529
Acoustic noise level51 dB conforming to 86/188/EEC
Assembly / installation styleWith heat sink
ATV212HU40N4LCD — Environmental
ParameterValue
Operating ambient temperature-10...40 °C (without derating) 40...50 °C (with derating factor)
Operating altitude1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3 5...95 % without dripping water conforming to IEC 60068-2-3
Storage / transport temperature-25...70 °C
Pollution degree3 conforming to IEC 61800-5-1
Vibration resistance1.5 mm (f= 3...13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8
ATV212HU40N4LCD — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 environments 2 category C3 IEC 61800-3 environments 1 category C2 IEC 61800-3 IEC 61800-3 environments 2 category C2 UL Type 1 EN 61800-3 environments 2 category C2 EN 61800-5-1 EN 55011 class A group 1 IEC 61800-3 category C2 EN 61800-3 environments 1 category C1 EN 61800-3 environments 2 category C3 IEC 61800-3 environments 1 category C3 EN 61800-3 category C3 EN 61800-3 environments 2 category C1 IEC 61800-5-1 EN 61800-3 IEC 61800-3 environments 1 category C1 EN 61800-3 environments 1 category C3 IEC 61800-3 environments 2 category C1 IEC 61800-3 category C3 EN 61800-3 environments 1 category C2 EN 61800-3 category C2
ATV212HU40N4LCD — Communication
ParameterValue
Communication protocolsLonWorks APOGEE FLN Modbus BACnet METASYS N2

Product details

The ATV212HU40N4LCD is a 4 kW / 5 hp variable speed drive from the Altivar 212 series, designed for asynchronous motors on 380-480 V three-phase supplies. It ships with a built-in Class C2 EMC filter, so you can skip the external filter for most European industrial environments — that saves a DIN-rail slot and about 15 minutes of panel wiring at commissioning.

Rated motor power is 4 kW (5 hp) at 380-480 V, line current 8.1 A at 380 V and 6.4 A at 480 V. That puts it squarely on a standard 4-pole induction motor for a pump, fan, or small conveyor — not oversized, not marginal. The integrated PI regulator handles closed-loop pressure or flow control without an external controller. The drive carries full motor and line protection: thermal overload, short-circuit between motor phases, input phase loss, DC bus overvoltage, and PTC probe input for motor thermal protection. That means you can usually skip a separate motor protection relay — the drive handles it internally, which simplifies the BOM and the panel layout. Operating altitude is rated to 1000 m without derating; between 1000 and 3000 m derate 1 % per 100 m, and the Corner Grounded distribution network is limited to 2000 m. If your site is above 1000 m, factor that into the sizing — a 4 kW motor at 1500 m needs about 5 % headroom.

Where this drive class is used

Altivar 212 drives are built for HVAC and industrial pumping, fan, and compressor applications — constant-torque and variable-torque loads in commercial buildings, water treatment, and light industrial lines. The integrated EMC filter at C2 level means it meets the conducted emission limits for most European industrial power networks without add-on hardware.

Frequently asked questions

What compliance documentation does the ATV212HU40N4LCD carry?

The drive carries CE marking and complies with IEC 61800-3 (environments 1 and 2, categories C1, C2, C3), IEC 61800-5-1, EN 61800-5-1, EN 55011 Class A Group 1, and UL Type 1. The integrated EMC filter is Class C2.

Where can I buy the ATV212HU40N4LCD?

The ATV212HU40N4LCD is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
ATV212HU40N4LCD