Specifications

ATV212WU30N4CZH28 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV212
Product range / familyAltivar 212
ATV212WU30N4CZH28 — Power & Output
ParameterValue
Motor power (kW)3 kW
Continuous output current7.2 A at 380 V 7.2 A at 460 V
Max. transient current7.9 A for 60 s
Apparent power5.5 kVA at 380 V
ATV212WU30N4CZH28 — Input / Supply
ParameterValue
Rated supply voltage range380...480 V - 15...10 %
Input line current6.2 A at 380 V 5 A at 480 V
Network number of phases3 phases
ATV212WU30N4CZH28 — Control & Performance
ParameterValue
Output frequency range0.5...200 Hz
Asynchronous motor control modesVoltage/frequency ratio, automatic IR compensation (U/f + automatic Uo) Voltage/frequency ratio, 2 points Voltage/frequency ratio, 5 points Flux vector control without sensor, standard Voltage/frequency ratio - Energy Saving, quadratic U/f
ATV212WU30N4CZH28 — Protection & EMC
ParameterValue
Integrated EMC filter classClass C1 EMC filter integrated
Protection functionsOverheating protection: drive Thermal power stage: drive Short-circuit between motor phases: drive Input phase breaks: drive Overcurrent between output phases and earth: drive Overvoltages on the DC bus: drive Break on the control circuit: drive Against exceeding limit speed: drive Line supply overvoltage and undervoltage: drive Line supply undervoltage: drive Against input phase loss: drive Thermal protection: motor Motor phase break: motor With PTC probes: motor
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
Prospective short-circuit current (Isc)5 kA
ATV212WU30N4CZH28 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP54 conforming to EN/IEC 61800-5-1 IP54 conforming to EN/IEC 60529
Acoustic noise level55 dB conforming to 86/188/EEC
Assembly / installation styleWith heat sink
ATV212WU30N4CZH28 — Environmental
ParameterValue
Operating ambient temperature-10...40 °C (without derating) 40...50 °C (with derating factor)
Operating altitude1000...3000 m limited to 2000 m for the Corner Grounded distribution network with current derating 1 % per 100 m <= 1000 m without derating
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3 5...95 % without dripping water conforming to IEC 60068-2-3
Storage / transport temperature-25...70 °C
Pollution degree3 conforming to IEC 61800-5-1
Vibration resistance1.5 mm (f= 3...13 Hz) conforming to EN/IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8
ATV212WU30N4CZH28 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-5-1 IEC 61800-3 environments 2 category C1 IEC 61800-3 IEC 61800-3 environments 1 category C3 EN 61800-3 EN 61800-3 environments 1 category C2 IEC 61800-3 category C1 EN 61800-3 environments 1 category C3 EN 61800-3 environments 2 category C2 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 1 category C2 EN 61800-3 category C1 EN 61800-3 environments 1 category C1 EN 61800-3 environments 2 category C3 EN 55011 group 1 class B IEC 61800-3 environments 2 category C3 EN 61800-3 environments 2 category C1 IEC 61800-3 environments 2 category C2 EN 61800-5-1
ATV212WU30N4CZH28 — Communication
ParameterValue
Communication protocolsBACnet LonWorks METASYS N2 Modbus APOGEE FLN

Product details

The Schneider Electric ATV212WU30N4CZH28 is an Altivar 212 variable speed drive sized for a 3 kW (4 hp) asynchronous motor on a 380…480 V three-phase supply. It carries an integrated Class C1 EMC filter, which means it meets conducted-emission limits for both residential and industrial environments without an external filter — a real space-saver in a panel where EMC compliance is already on the checklist. The drive communicates over a 2-wire RS-485 bus using Modbus RTU at 9600 or 19200 bps, addressing up to 247 nodes. That makes it straightforward to drop into a line controlled by a PLC or SCADA system without a gateway.

Switching frequency and motor protection

Switching frequency is adjustable from 6 to 16 kHz; run it above 12 kHz and you'll need to derate the output current. The drive includes a built-in PI regulator for closed-loop process control — useful for pump or fan applications where you want to hold pressure or flow without an external controller. Protection coverage is thorough: the drive monitors for input phase loss, DC bus overvoltage and undervoltage, motor thermal overload, short-circuits between motor phases and to ground, and PTC probe inputs from the motor. That last one — PTC probes — means you can wire motor thermistors directly to the analog input terminals without an external relay.

The drive measures 340 mm high by 230 mm wide by 208 mm deep, with a heat sink on the back. Mount it vertically within ±10 degrees for proper airflow. Altitude derating kicks in above 1000 m — 1 % per 100 m up to 3000 m, and limited to 2000 m for corner-grounded distribution networks. Operating humidity range is 5 to 95 % non-condensing.

The drive carries CE marking and is designed to IEC 61800-5-1 (safety) and IEC 61800-3 (EMC). It meets multiple EMC environment categories — C1, C2, and C3 depending on installation — and is listed under EN 55011 Group 1 Class B for conducted emissions. Noise level is rated at 55 dB.

Frequently asked questions

Where can I buy ATV212WU30N4CZH28 and get a price?

This drive is sourced to order through independent distribution. Submit an RFQ for current pricing and availability — both are confirmed at quote time and vary with market conditions.

What compliance documentation does ATV212WU30N4CZH28 carry?

CE marked, designed to IEC 61800-5-1 and IEC 61800-3, meets EN 55011 Group 1 Class B. EMC categories C1, C2, and C3 are covered depending on installation environment.

What is the switching frequency range on this drive?

Adjustable from 6 to 16 kHz. Above 12 kHz you need to derate the output current per the thermal curve.