Skip to main content
Schneider Electric ATV21HD22M3X — AC Drive (VFD) 240V

Schneider Electric ATV21HD22M3X AC Drive (VFD) 240V, 22 kW

MPNATV21HD22M3X
Active

Schneider Electric Altivar 21 ATV21HD22M3X AC drive (VFD), 22 kW, 200-240 V 3-phase, 66.4 A line current, 33.5 kVA, IP20, without EMC filter.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV21HD22M3X — Electrical Output
ParameterValue
Motor power (normal / heavy duty)22 kW
ATV21HD22M3X — Approvals
ParameterValue
Compliance standardsEN 61800-3 environments 1 category C3 EN 61800-3 IEC 61800-3 environments 2 category C1 IEC 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C2 IEC 61800-3 UL Type 1 EN 61800-3 environments 1 category C2 IEC 61800-5-1 EN 61800-3 environments 2 category C1 EN 61800-3 environments 2 category C2 EN 61800-3 environments 2 category C3 IEC 61800-3 environments 2 category C3 EN 61800-3 environments 1 category C1 EN 61800-5-1 IEC 61800-3 environments 1 category C3 IEC 61800-3 environments 1 category C2
ATV21HD22M3X — Mechanical
ParameterValue
Height16.5 in (420 mm)
Width9.4 in (240 mm)

Product details

22 kW, 200-240 V — what it handles

The ATV21HD22M3X is a 22 kW Altivar 21 variable-frequency drive for three-phase asynchronous motors on a 200-240 V supply — the line current at 240 V is 66.4 A, and at 200 V it draws 80.4 A, so the feeder and branch protection need to be sized for the lower-voltage end of the range. Apparent power is 33.5 kVA at 240 V, and the drive delivers a transient overtorque of 120 % for 60 s — enough to break a stalled pump or conveyor start without tripping, as long as the upstream circuit is coordinated for the inrush.

Switching frequency and derating

Switching frequency is adjustable from 6 to 16 kHz, with a derating factor required above 8 kHz — running at 16 kHz quiets the motor whine but cuts the continuous output current, so if you need full rated torque at the shaft, keep the carrier at 8 kHz or below. The drive includes an adjustable PI regulator for closed-loop process control (pressure, flow, level) and the speed accuracy is ±10 % of nominal slip from 0.2 Tn to Tn — adequate for most fan and pump applications that don't need encoder feedback.

Standards and compliance package

The ATV21HD22M3X carries CE marking and meets EN/IEC 61800-3 for EMC environments 1 and 2, categories C1 through C3, plus EN/IEC 61800-5-1 for safety — so it's accepted across most industrial installations in Europe and markets that harmonise with IEC standards. It is quoted to order against the BOM; availability and current pricing confirmed at RFQ.

Mounting and environment

Dimensions are 16.5 x 9.4 x 4.8 inches (H x W x D) — the heatsink is integral, so panel cut-out and clearance for airflow need to account for the full depth plus a bend radius for the power cables. Operating altitude is limited to 2000 m for corner-grounded distribution networks; above that, derate per the manual. Pollution degree 3 per IEC 61800-5-1 means it's suited for industrial environments with conductive dust or humidity, but not for direct washdown — IP20, no EMC filter fitted.

Frequently asked questions

How can I order the ATV21HD22M3X or get a quote?

This drive is quoted to order through independent distribution.

What is the ATV21HD22M3X's line current at 240 V?

At 240 V the line current is 66.4 A; at 200 V it is 80.4 A. Size the branch circuit for the higher current at the lower voltage end of the range.

What compliance documentation does Schneider provide for the ATV21HD22M3X?

The drive is CE marked and complies with EN/IEC 61800-3 (EMC environments 1 and 2, categories C1-C3) and EN/IEC 61800-5-1 (safety). Standards documentation is available from the manufacturer.

MPN
ATV21HD22M3X