Skip to main content
Schneider Electric ATV21WD15N4 — AC Drive (VFD) 480V

Schneider Electric ATV21WD15N4 AC Drive, 15 kW, 380-480 V

MPNATV21WD15N4
Obsolete

Schneider Electric Altivar 21 ATV21WD15N4 AC drive, 15 kW, 380-480 V, 3-phase, 22.6 A line current at 480 V, integrated Class A EMC filter, CE marked.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026

Specifications

ATV21WD15N4 — Identification
ParameterValue
Product typeVariable speed drive
Product range / familyAltivar 21
ATV21WD15N4 — Power & Output
ParameterValue
Motor power (kW)15 kW
Max. transient current33.6 A 60 s
Apparent power23.2 kVA 380 V
ATV21WD15N4 — Input / Supply
ParameterValue
Input line current22.6 A 480 V 28.4 A 380 V
ATV21WD15N4 — Control & Performance
ParameterValue
Output frequency range0.5...200 Hz
Asynchronous motor control modesQuadratic voltage/frequency ratio Constant voltage/frequency ratio Constant voltage/frequency ratio with automatic IR compensation Energy saving ratio Current flux vector control (FVC) without speed feedback
ATV21WD15N4 — Protection & EMC
ParameterValue
Integrated EMC filter classClass A EMC filter integrated
EMC immunity tests1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11
ATV21WD15N4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP54 EN 60530 IP54 EN 61800-5-2 IP54 IEC 60529 IP54 IEC 61800-5-1
Acoustic noise level57.4 dB 86/188/EEC
Assembly / installation styleWith heat sink
ATV21WD15N4 — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) (without derating) 104...122 °F (40...50 °C) (with derating factor)
Operating altitude3280.84...9842.52 ft (1000...3000 m) limited to 2000 m for the Corner Grounded distribution network
Relative humidity5...95 % without condensation IEC 60068-2-3 5...95 % without dripping water IEC 60068-2-3
Storage / transport temperature-13...158 °F (-25...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1 gn (f= 13...200 Hz) conforming to EN/IEC 60068-2-8 1.5 mm (f= 3...13 Hz) conforming to EN/IEC 60068-2-6
ATV21WD15N4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceEN 61800-5-1 IEC 61800-3 category C2 EN 61800-3 environments 2 category C1 IEC 61800-3 environments 1 category C2 EN 55011 class A group 1 EN 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C3 IEC 61800-5-1 EN 61800-3 environments 1 category C3 IEC 61800-3 EN 61800-3 category C2 IEC 61800-3 environments 1 category C1 IEC 61800-3 category C3 EN 61800-3 environments 1 category C1 IEC 61800-3 environments 2 category C2 EN 61800-3 environments 2 category C3 IEC 61800-3 environments 1 category C3 EN 61800-3 EN 61800-3 category C3 IEC 61800-3 environments 2 category C1 EN 61800-3 environments 2 category C2
ATV21WD15N4 — Communication
ParameterValue
Communication protocolsModbus

Product details

15 kW VFD for asynchronous motors

The ATV21WD15N4 is a 15 kW Altivar 21 variable frequency drive from Schneider Electric, designed for three-phase asynchronous motors in HVAC and building management applications. It accepts a 380...480 V supply at -15...10 % tolerance, drawing 22.6 A line current at 480 V or 28.4 A at 380 V. The drive's 12...16 kHz adjustable switching frequency lets you trade audible motor noise against thermal derating — at 16 kHz the continuous output current drops, so match the switching frequency to the load duty cycle before locking the BOM.

Panel fit and mounting constraints

The enclosure measures 22.05 in high by 11.4 in wide by 12.4 in deep (560 x 290 x 315 mm), with a vertical mounting orientation required (±10° tolerance). The heat sink assembly needs clearance for airflow — plan the gland plate and cable entry accordingly. Operating altitude is limited to 2000 m for corner-grounded distribution networks; above that up to 3000 m with derating. Pollution degree 2 per IEC 61800-5-1 means the drive suits typical control-room environments, not heavy dust or conductive contamination.

EMC compliance and fieldbus options

The drive ships with an integrated Class A EMC filter and carries CE marking under EN 61800-5-1 and IEC 61800-3 (category C2 for first environment, C3 for second). It meets EN 55011 Class A Group 1 conducted and radiated limits — suitable for industrial zones but may need additional filtering for residential or light-commercial installations. Built-in Modbus RTU over a 2-wire RS-485 physical interface (9600 or 19200 bps, configurable parity) supports up to 247 addresses. Optional communication cards add BACnet, LonWorks, Metasys N2, or Apogee FLN for building automation integration.

Frequently asked questions

What is the ATV21WD15N4 used for?

It is a 15 kW variable frequency drive for three-phase asynchronous motors in HVAC, pumping, and building automation systems. The integrated PI regulator handles closed-loop pressure or flow control without an external controller.

What compliance documentation does Schneider Electric provide for ATV21WD15N4?

The drive is CE marked and complies with EN 61800-5-1 (safety), IEC 61800-3 (EMC categories C2/C3), and EN 55011 Class A Group 1. It also meets IEC 60068-2-27 shock resistance (15 gn, 11 ms) and IEC 60068-2-3 humidity (5-95% RH without condensation).

What is the closest alternative to ATV21WD15N4 in the Altivar 21 family?

Within the same Altivar 21 series, the closest peer is the ATV21WD11N4 (11 kW) for a lower power point, or the ATV21WD18N4 (18.5 kW) for a step up. All share the same form factor, fieldbus options, and EMC filter architecture — the deciding factor is the motor nameplate power.

MPN