Skip to main content
Schneider Electric ATV350U07N4I — AC Drive (VFD) 480V

Schneider Altivar ATV350U07N4I, 0.75 kW drive, 3.8 A, STO

MPNATV350U07N4I
Active

Schneider Electric Altivar Machine ATV350, ATV350U07N4I, 0.75 kW / 3.8 A, 400-480 V 3-phase, integrated Class C2 EMC filter, STO, EtherCAT/EtherNet/IP.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV350U07N4I — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV350
Product range / familyAltivar Machine ATV350
ATV350U07N4I — Power & Output
ParameterValue
Motor power (kW)0.75 kW conveying applications
Continuous output current3.8 A 2...16 kHz conveying applications
Max. transient current7.6 A 3 s conveying applications) 5.7 A 60 s conveying applications)
Apparent power1.5 kVA 400...480 V conveying applications)
ATV350U07N4I — Input / Supply
ParameterValue
Rated supply voltage range400...480 V +/-5 %
Input line current3.8 A 400...480 V conveying applications)
Internal/auxiliary suppliesInternal supply for logic inputs 24 V DC
ATV350U07N4I — Control & Performance
ParameterValue
Asynchronous motor control modesU/F vector control Sensorless vector control (SVC) Energy saving control Closed-loop control with encoder
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop
ATV350U07N4I — Protection & EMC
ParameterValue
Integrated EMC filter classClass C2 EMC filter integrated EN 61508 32.8 ft (10 m) Class C2 EMC filter integrated EN 61800-5-1 32.8 ft (10 m) Class C2 EMC filter integrated EN 61800-5-2 32.8 ft (10 m) Class C2 EMC filter integrated IEC 60529 32.8 ft (10 m) Class C2 EMC filter integrated UL 50E 32.8 ft (10 m) Class C2 EMC filter integrated machinery directive 2006/42/EC 32.8 ft (10 m)
Protection functionsLine supply phase loss drive Motor phase loss motor Line supply overvoltage and undervoltage drive Overheating protection drive Overload motor With PTC probes motor Short-circuit between motor phases drive Overcurrent between output phases and earth drive
ATV350U07N4I — Mechanical & Cooling
ParameterValue
IP degree of protectionIP54 conforming to EN 61508 IP54 conforming to EN 61800-5-1 IP54 conforming to EN 61800-5-2 IP54 conforming to IEC 60529 IP54 conforming to UL 50E IP54 conforming to machinery directive 2006/42/EC
Cooling methodAN (air natural)
ATV350U07N4I — Environmental
ParameterValue
Operating ambient temperature-22...140 °F (-30...60 °C) (with current derating of 2.5 % per °C above 40 °C)
Operating altitude3280.84 ft (1000 m) with current derating of 0.5 % per additional 100 m
Relative humidity5...95 % without condensation EN/IEC 60068-2-3
Storage / transport temperature-22...140 °F (-30...60 °C)
Pollution degree2
Vibration resistance1 mm (f= 5...13 Hz) conforming to DNVGL-GC-0339 0.7 gn (f= 13...100 Hz) conforming to DNVGL-GC-0339
ATV350U07N4I — Approvals
ParameterValue
Certifications & markingCE UL CULus IEC UKCA
Standards complianceIEC 61800-5-1 IEC 61800-3 UL 508C IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C3 IEC 60721-3 IEC 61508 IEC 13849-1
ATV350U07N4I — Communication
ParameterValue
Communication protocolsEtherNet/IP EtherCAT IO-Link Modbus TCP PROFINET

Product details

The ATV350U07N4I is a 0.75 kW Altivar Machine drive rated for 3.8 A output at 400-480 V three-phase. It targets asynchronous and synchronous motors in conveying and general machine applications. The integrated Class C2 EMC filter covers conducted emissions for first-environment (residential) installations up to 10 m cable, which simplifies panel layout — no external filter needed for most European CE-marked machines.

Network and safety

Two Ethernet ports on M12 connectors support EtherCAT, EtherNet/IP, Modbus TCP, or PROFINET via the IO scanner. The drive includes STO (Safe Torque Off) as a standard safety function, meeting SIL 3 / PL e per IEC 61508 and EN 13849-1. Switching frequency is adjustable 2…16 kHz; derate output current 0.5 % per 100 m above 1000 m altitude.

Frequently asked questions

What safety functions does this drive include?

STO (Safe Torque Off) is integrated, compliant with IEC 61508 and EN 13849-1.

What network protocols does the ATV350U07N4I support?

The two M12 Ethernet ports support EtherCAT, EtherNet/IP, Modbus TCP, and PROFINET via the IO scanner.

What is the output frequency range?

1 to 599 Hz, with 0.1 Hz resolution.

MPN