Skip to main content
Schneider Electric ATV350U15N4W — AC Drive (VFD) 480V

Schneider ATV350U15N4W Altivar Machine Drive, 1.5 kW, STO

MPNATV350U15N4W
Active

Schneider Altivar Machine ATV350, basic version, 1.5 kW, 3-phase 400-480 V, 6.3 A output, STO safety, integrated C2 EMC filter.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV350U15N4W — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV350
Product range / familyAltivar Machine ATV350
ATV350U15N4W — Power & Output
ParameterValue
Motor power (kW)1.5 kW conveying applications
Continuous output current6.3 A 2...16 kHz conveying applications
Max. transient current12.6 A 3 s conveying applications) 9.4 A 60 s conveying applications)
Apparent power2.5 kVA 400...480 V conveying applications)
ATV350U15N4W — Input / Supply
ParameterValue
Rated supply voltage range400...480 V +/-5 %
Input line current6.3 A 400...480 V conveying applications)
Internal/auxiliary suppliesInternal supply for logic inputs 24 V DC
ATV350U15N4W — Control & Performance
ParameterValue
Asynchronous motor control modesU/F vector control Sensorless vector control (SVC) Energy saving control Closed-loop control with encoder
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop
ATV350U15N4W — Protection & EMC
ParameterValue
Integrated EMC filter classClass C2 EMC filter integrated EN 61508 32.8 ft (10 m) Class C2 EMC filter integrated EN 61800-5-1 32.8 ft (10 m) Class C2 EMC filter integrated EN 61800-5-2 32.8 ft (10 m) Class C2 EMC filter integrated IEC 60529 32.8 ft (10 m) Class C2 EMC filter integrated UL 50E 32.8 ft (10 m) Class C2 EMC filter integrated machinery directive 2006/42/EC 32.8 ft (10 m)
Protection functionsLine supply phase loss drive Motor phase loss motor Line supply overvoltage and undervoltage drive Overheating protection drive Overload motor With PTC probes motor Short-circuit between motor phases drive Overcurrent between output phases and earth drive
ATV350U15N4W — Mechanical & Cooling
ParameterValue
IP degree of protectionIP66 conforming to EN 61508 IP66 conforming to EN 61800-5-1 IP66 conforming to EN 61800-5-2 IP66 conforming to IEC 60529 IP66 conforming to UL 50E IP66 conforming to machinery directive 2006/42/EC
Cooling methodAN (air natural)
ATV350U15N4W — Environmental
ParameterValue
Operating ambient temperature-22...140 °F (-30...60 °C) (with current derating of 2.5 % per °C above 40 °C)
Operating altitude3280.84 ft (1000 m) with current derating of 0.5 % per additional 100 m
Relative humidity5...95 % without condensation EN/IEC 60068-2-3
Storage / transport temperature-22...140 °F (-30...60 °C)
Pollution degree2
Vibration resistance1 mm (f= 5...13 Hz) conforming to DNVGL-GC-0339 0.7 gn (f= 13...100 Hz) conforming to DNVGL-GC-0339
ATV350U15N4W — Approvals
ParameterValue
Certifications & markingCE UL CULus IEC UKCA
Standards complianceIEC 61800-5-1 IEC 61800-3 UL 508C IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C3 IEC 60721-3 IEC 61508 IEC 13849-1
ATV350U15N4W — Communication
ParameterValue
Communication protocolsEtherNet/IP EtherCAT IO-Link Modbus TCP PROFINET

Product details

The Schneider ATV350U15N4W is a basic version Altivar Machine ATV350 drive, sized for 1.5 kW asynchronous or synchronous motors on 400-480 V three-phase supply. It delivers 6.3 A continuous output current across a 1-599 Hz frequency range, with an integrated Class C2 EMC filter for conducted emissions compliance up to 10 m cable runs. The drive includes STO (Safe Torque Off) as a standard safety function, meeting IEC 61508 and IEC 13849-1 requirements for safe-stop integration.

The 6.3 A output current is rated for standard conveying applications — that's the duty point where the drive delivers full rated current without derating. For other load profiles or ambient temperatures above 40 °C, the 3-phase design includes a current derating of 2.5 % per °C, so panel placement and airflow matter. The drive is naturally air-cooled (AN), meaning no fan to fail, but it needs clear space around the wall-mounted enclosure for convection. Switching frequency is adjustable from 2 to 16 kHz; above the default, you lose output current capacity at the rate of 0.5 % per additional 100 m of altitude above 1000 m. At sea level, the 2-16 kHz range covers most motor noise and efficiency trade-offs, but if you need full rated current at 16 kHz, check the thermal derating curve in the manual.

The drive carries CE, UL, CULus, IEC, and UKCA markings, and complies with IEC 61800-5-1 (safety), IEC 61800-3 (EMC environments 1 category C2 and 2 category C3), UL 508C, IEC 60721-3 (environmental), and IEC 61508 / IEC 13849-1 (functional safety). The integrated EMC filter covers conducted emissions for both C2 and C3 environments, so no external filter is needed for most installations. Documentation includes the standard EU Declaration of Conformity and manufacturer's test certificates.

Frequently asked questions

What safety functions does it include?

The drive includes STO (Safe Torque Off) as a standard safety function, compliant with IEC 61508 and IEC 13849-1.

What compliance markings does it carry?

It carries CE, UL, CULus, IEC, and UKCA markings, and complies with IEC 61800-5-1, IEC 61800-3, UL 508C, and other relevant standards.

MPN