Skip to main content
Schneider Electric ATV350U55N4W — AC Drive (VFD) 480V

Schneider ATV350U55N4W Altivar Machine Drive, 5.5 kW, 19.6 A

MPNATV350U55N4W
Active

Schneider Electric Altivar Machine ATV350, basic version, 5.5 kW / 19.6 A output, 400-480 V 3-phase, wall-mounted, integrated Class C2 EMC filter, STO safety function.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV350U55N4W — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV350
Product range / familyAltivar Machine ATV350
ATV350U55N4W — Power & Output
ParameterValue
Motor power (kW)5.5 kW conveying applications
Continuous output current19.6 A 2...16 kHz conveying applications
Max. transient current39.2 A 3 s conveying applications) 29.4 A 60 s conveying applications)
Apparent power8 kVA 400...480 V conveying applications)
ATV350U55N4W — Input / Supply
ParameterValue
Rated supply voltage range400...480 V +/-5 %
Input line current19.6 A 400...480 V conveying applications)
Internal/auxiliary suppliesInternal supply for logic inputs 24 V DC
ATV350U55N4W — Control & Performance
ParameterValue
Asynchronous motor control modesU/F vector control Sensorless vector control (SVC) Energy saving control Closed-loop control with encoder
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop
ATV350U55N4W — Protection & EMC
ParameterValue
Integrated EMC filter classClass C2 EMC filter integrated EN 61508 32.8 ft (10 m) Class C2 EMC filter integrated EN 61800-5-1 32.8 ft (10 m) Class C2 EMC filter integrated EN 61800-5-2 32.8 ft (10 m) Class C2 EMC filter integrated IEC 60529 32.8 ft (10 m) Class C2 EMC filter integrated UL 50E 32.8 ft (10 m) Class C2 EMC filter integrated machinery directive 2006/42/EC 32.8 ft (10 m)
Protection functionsLine supply phase loss drive Motor phase loss motor Line supply overvoltage and undervoltage drive Overheating protection drive Overload motor With PTC probes motor Short-circuit between motor phases drive Overcurrent between output phases and earth drive
ATV350U55N4W — Mechanical & Cooling
ParameterValue
IP degree of protectionIP66 conforming to EN 61508 IP66 conforming to EN 61800-5-1 IP66 conforming to EN 61800-5-2 IP66 conforming to IEC 60529 IP66 conforming to UL 50E IP66 conforming to machinery directive 2006/42/EC
Cooling methodAN (air natural)
ATV350U55N4W — Environmental
ParameterValue
Operating ambient temperature-22...140 °F (-30...60 °C) (with current derating of 2.5 % per °C above 40 °C)
Operating altitude3280.84 ft (1000 m) with current derating of 0.5 % per additional 100 m
Relative humidity5...95 % without condensation EN/IEC 60068-2-3
Storage / transport temperature-22...140 °F (-30...60 °C)
Pollution degree2
Vibration resistance1 mm (f= 5...13 Hz) conforming to DNVGL-GC-0339 0.7 gn (f= 13...100 Hz) conforming to DNVGL-GC-0339
ATV350U55N4W — Approvals
ParameterValue
Certifications & markingCE UL CULus IEC UKCA
Standards complianceIEC 61800-5-1 IEC 61800-3 UL 508C IEC 61800-3 environments 1 category C2 IEC 61800-3 environments 2 category C3 IEC 60721-3 IEC 61508 IEC 13849-1
ATV350U55N4W — Communication
ParameterValue
Communication protocolsEtherNet/IP EtherCAT IO-Link Modbus TCP PROFINET

Product details

The Schneider ATV350U55N4W is a basic-version Altivar Machine drive rated for 5.5 kW motor power and 19.6 A continuous output current on 400-480 V three-phase supply. It's built for asynchronous and synchronous motors, with an output frequency range of 1-599 Hz and a switching frequency adjustable from 2-16 kHz (derate current 0.5% per 100 m above 1000 m altitude). The integrated Class C2 EMC filter covers 10 m cable runs, so you can skip the external filter for most industrial environments — that's one less SKU on the shelf.

The 19.6 A output current is the continuous rating at the drive's nominal switching frequency. Above 40°C ambient, derate 2.5% per °C. Wall-mount only — no flange kit option listed, so plan for vertical surface with clearance for the natural convection cooling (AN cooling type). Dimensions are 12.2 in high, 20.6 in wide, 9.2 in deep; that's a fairly wide footprint for a 5.5 kW drive, so check your panel door swing before committing.

Compliance and approvals — what's on the nameplate

Marked CE, UL, cULus, IEC, and UKCA — covers North American and European installations. Standards include IEC 61800-5-1 (safety), IEC 61800-3 (EMC environments 1 category C2 and 2 category C3), UL 508C, plus functional safety per IEC 61508 and IEC 13849-1. The integrated STO (safe torque off) function is SIL-rated per those standards, so you can wire the safety circuit directly without an external safety relay for most stop categories.

Frequently asked questions

What compliance documentation does this drive carry?

Marked CE, UL, cULus, IEC, and UKCA. Complies with IEC 61800-5-1, IEC 61800-3 (environments 1 C2 and 2 C3), UL 508C, IEC 61508, and IEC 13849-1. Integrated STO safety function.

MPN
ATV350U55N4W