The ATV350U75N4W is a 7.5 kW Altivar Machine ATV350 drive rated for 24.7 A continuous output current on a 400-480 V 3-phase supply. It handles asynchronous and synchronous motors with an output frequency range of 1-599 Hz. The integrated Class C2 EMC filter covers both first and second environment categories (C2 and C3 per IEC 61800-3), so you can skip an external filter for most panel builds. STO (Safe Torque Off) is built in — no separate safety module needed for that function.
Note the 3-phase supply derating: current drops 2.5 % per °C above 40 °C ambient, so at 50 °C you'd have about 22.3 A available. The switching frequency spans 2-16 kHz; higher switching reduces motor noise but also derates output — the drive's thermal model accounts for it automatically. Line current matches output current at 24.7 A, which simplifies branch circuit sizing.