Specifications

ATV6000C113A4242ND — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV6000
Product range / familyAltivar Process ATV6000
ATV6000C113A4242ND — Power & Output
ParameterValue
Motor power (kW)900 kW normal duty 720 kW heavy duty
Continuous output current120 A heavy duty 150 A normal duty
Max. transient current225 A 3 s heavy duty) 225 A 3 s normal duty)
Apparent power1130 kVA
ATV6000C113A4242ND — Input / Supply
ParameterValue
Rated supply voltage range4.16 kV +/- 10 %
Input line current125 A heavy duty 157 A normal duty
Internal/auxiliary suppliesInternal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 12 kVA
ATV6000C113A4242ND — Control & Performance
ParameterValue
Output frequency range0.1...120 Hz
Asynchronous motor control modesClosed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor
ATV6000C113A4242ND — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated IEC 61800-3 category C3 control Integrated IEC 61800-3 category C4 Power
Protection functionsLine supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overvoltages on the DC bus drive Thermal overload for transformer drive Cabinet overheating drive Overcurrent drive Overload drive Short-circuit protection drive IGBT for each cell drive Thermal protection motor Motor phase break motor Motor earth fault motor Break on the control circuit drive Fan monitoring drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)31.5 kA 150 ms
ATV6000C113A4242ND — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 conforming to IEC 60529
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure
ATV6000C113A4242ND — Environmental
ParameterValue
Operating ambient temperature32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport
Operating altitude3280.84...6561.68 ft (1000...2000 m) with derating factor
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature32...122 °F (0...50 °C)
Pollution degree2 IEC 61800-5-1
ATV6000C113A4242ND — Approvals
ParameterValue
Certifications & markingCULus CE UKCA
Standards complianceIEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076 UL 347A
ATV6000C113A4242ND — Communication
ParameterValue
Communication protocolsEthernet IP/Modbus TCP

Product details

What this drive is and what it powers

The ATV6000C113A4242ND is a Schneider Electric Altivar Process ATV6000 AC drive rated for 900 kW normal duty and 720 kW heavy duty motor power, with a corresponding line current of 157 A normal duty and 125 A heavy duty. It uses a 24-pulse diode rectifier bridge input topology, which keeps total harmonic current distortion (THDI) below 3% per IEEE 519-1992 — that means no external harmonic filter needed for most plant distribution systems. The output stage is IGBT inverter cells with multilevel PWM, driving asynchronous, synchronous, or permanent magnet motors.

Physical footprint and enclosure

This drive ships as a floor-standing enclosure measuring 140.2 in wide by 102.4 in tall by 55.1 in deep — plan the installation pad and overhead crane access accordingly. Cable entry is at the bottom; the enclosure includes the HMI (10-inch LCD touch screen), cooling fans, power cells, phase-shifting transformer, plinth, and medium voltage arrestors as provided equipment. Forced convection cooling with a noise level of 80 dB — factor ear protection into the commissioning plan.

Power quality and losses

Power factor is 96% with apparent power rating of 1130 kVA. Power losses are 39.2 kW in normal duty and 31.4 kW in heavy duty — this heat goes into the room, so the ventilation system needs to handle it. The drive meets IEC 61800-3 category C3 (control) and C4 (power) EMC filter levels, and carries pollution degree 2 per IEC 61800-5-1.

Approvals include CULus, CE, and UKCA, with standards compliance to IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, EN/IEC 60076, and UL 347A.

Frequently asked questions

What compliance documentation does Schneider Electric provide for ATV6000C113A4242ND?

The drive carries CULus, CE, and UKCA markings and complies with IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, EN/IEC 60076, and UL 347A. Standard Schneider documentation includes the product manual and declaration of conformity.