Specifications

ATV6000C125A4242ND — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV6000
Product range / familyAltivar Process ATV6000
ATV6000C125A4242ND — Power & Output
ParameterValue
Motor power (kW)1000 kW normal duty 950 kW heavy duty
Continuous output current166 A normal duty 159 A heavy duty
Max. transient current249 A 3 s normal duty) 298 A 3 s heavy duty)
Apparent power1250 kVA
ATV6000C125A4242ND — Input / Supply
ParameterValue
Rated supply voltage range4.16 kV +/- 10 %
Input line current174 A normal duty 165 A heavy duty
Internal/auxiliary suppliesInternal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 5 kVA
ATV6000C125A4242ND — Control & Performance
ParameterValue
Output frequency range0.1...120 Hz
Asynchronous motor control modesClosed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor
ATV6000C125A4242ND — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated IEC 61800-3 category C3 control Integrated IEC 61800-3 category C4 Power
Protection functionsLine supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overvoltages on the DC bus drive Thermal overload for transformer drive Cabinet overheating drive Overcurrent drive Overload drive Short-circuit protection drive IGBT for each cell drive Thermal protection motor Motor phase break motor Motor earth fault motor Break on the control circuit drive Fan monitoring drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)31.5 kA 150 ms
ATV6000C125A4242ND — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 conforming to IEC 60529
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure
ATV6000C125A4242ND — Environmental
ParameterValue
Operating ambient temperature32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport
Operating altitude3280.84...6561.68 ft (1000...2000 m) with derating factor
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature32...122 °F (0...50 °C)
Pollution degree2 IEC 61800-5-1
ATV6000C125A4242ND — Approvals
ParameterValue
Certifications & markingCULus CE UKCA
Standards complianceIEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076 UL 347A
ATV6000C125A4242ND — Communication
ParameterValue
Communication protocolsEthernet IP/Modbus TCP

Product details

Motor power and harmonic performance

The ATV6000C125A4242ND: Rated 1000 kW normal duty / 950 kW heavy duty at the shaft, with a corresponding apparent power of 1250 kVA. The 24-pulse diode rectifier front end keeps total harmonic current distortion below 3 % per IEEE 519-1992 — no external harmonic filter needed for most utility compliance points.

Line current and input topology

Draws 174 A line current in normal duty, 165 A in heavy duty. The 24-pulse rectifier cancels the 5th and 7th harmonics at the input, which is what delivers the sub-3 % THDI figure — a significant advantage for installations where transformer sizing or upstream harmonic limits are tight.

Physical footprint and enclosure

Floor-standing enclosure measures 108.3 in high × 148.03 in wide × 55.1 in deep. The bottom cable entry and forced-convection cooling suit a dedicated drive room or outdoor-rated shelter; the 80 dB noise level means hearing protection is needed within the enclosure perimeter.

Marked CULus, CE, UKCA, so it ships into North American and UK markets without additional certification delays.

Frequently asked questions

How can I get pricing and availability for ATV6000C125A4242ND?

Quoted to order against the BOM through independent distribution. Submit an RFQ for current pricing and lead time.

What compliance documentation does Schneider Electric provide for ATV6000C125A4242ND?

The drive carries CULus, CE, and UKCA markings. Standards include IEC 61800-3, IEC 61800-5-1, and UL 347A.

What is the closest alternative to ATV6000C125A4242ND in the Altivar Process family?

For a functionally similar unit within the same ATV6000 family, compare the power rating and input topology against other 24-pulse models in the range.

MPN
ATV6000C125A4242ND