Skip to main content
Schneider Electric ATV6000C138A6666ND — AC Drive (VFD) 480V

Schneider ATV6000C138A6666ND Altivar Process VFD, 1100 kW

MPNATV6000C138A6666ND
Active

Schneider Electric Altivar Process ATV6000, ATV6000C138A6666ND, 1100 kW normal duty / 1050 kW heavy duty, 3-phase, 30-pulse diode rectifier, 1380 kVA apparent power.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV6000C138A6666ND — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV6000
Product range / familyAltivar Process ATV6000
ATV6000C138A6666ND — Power & Output
ParameterValue
Motor power (kW)1100 kW normal duty 1050 kW heavy duty
Continuous output current115 A normal duty 110 A heavy duty
Max. transient current173 A 3 s normal duty) 206 A 3 s heavy duty)
Apparent power1380 kVA
ATV6000C138A6666ND — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current121 A normal duty 115 A heavy duty
Internal/auxiliary suppliesInternal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 5 kVA
ATV6000C138A6666ND — Control & Performance
ParameterValue
Output frequency range0.1...120 Hz
Asynchronous motor control modesClosed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor
ATV6000C138A6666ND — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated IEC 61800-3 category C3 control Integrated IEC 61800-3 category C4 Power
Protection functionsLine supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overvoltages on the DC bus drive Thermal overload for transformer drive Cabinet overheating drive Overcurrent drive Overload drive Short-circuit protection drive IGBT for each cell drive Thermal protection motor Motor phase break motor Motor earth fault motor Break on the control circuit drive Fan monitoring drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)31.5 kA 150 ms
ATV6000C138A6666ND — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 conforming to IEC 60529
Acoustic noise level83 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure
ATV6000C138A6666ND — Environmental
ParameterValue
Operating ambient temperature32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport
Operating altitude3280.84...6561.68 ft (1000...2000 m) with derating factor
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature32...122 °F (0...50 °C)
Pollution degree2 IEC 61800-5-1
ATV6000C138A6666ND — Approvals
ParameterValue
Certifications & markingCULus CE UKCA
Standards complianceIEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076 UL 347A
ATV6000C138A6666ND — Communication
ParameterValue
Communication protocolsEthernet IP/Modbus TCP

Product details

Ratings that define the fit

The ATV6000C138A6666ND: Line current is 121 A at normal duty and 115 A at heavy duty, with an apparent power rating of 1380 kVA. Power losses run 47.9 kW normal duty, 45.7 kW heavy duty — that heat lands in the enclosure, so forced convection cooling is integrated. The drive carries IEC 61800-3 category C3 (integrated) and C4 (power) EMC filters, covering conducted emissions for industrial second-environment installations.

Fieldbus and I/O architecture

Slot A accepts communication modules for Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), and EtherCAT. Slot B takes encoder interfaces (digital 5/12 V, analog, resolver, HTL) plus digital/analog I/O and relay extension modules. The control block includes two RJ45 ports for Ethernet IP/Modbus TCP and one for Modbus serial. Eight programmable digital inputs (24 V DC) are on board.

Physical scale and enclosure

Floor-standing enclosure measures 103.03 in high by 144.09 in wide by 55.1 in deep. Cable entry is at the bottom. The enclosure is light grey RAL 7035 and includes the plinth, power cells, medium-voltage arrestors, phase-shifting transformer, HMI, and cooling fans as provided equipment.

Frequently asked questions

What motor types does this drive support?

It is designed for asynchronous, synchronous, and permanent magnet motors.

What communication protocols are available?

Slot A modules support Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, screw terminals), and EtherCAT. The control block has two RJ45 ports for Ethernet IP/Modbus TCP and one for Modbus serial.

What are the key harmonic performance specs?

The 30-pulse rectifier achieves input current THDI below 3% per IEEE 519-1992.

MPN
ATV6000C138A6666ND