Schneider Electric ATV6000C150A3333NA3

Schneider Electric ATV6000C150A3333NA3 AC Drive, 1200 kW

MPN ATV6000C150A3333NA3
Active

Schneider Electric Altivar Process ATV6000 AC Drive, 1200 kW normal duty, 1070 kW heavy duty, 480 V, 18-pulse diode rectifier, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6000C150A3333NA3 specifications
ParameterValue
Input type18 pulse diode rectifier bridge
Display type10 inch LCD touch screen multi-language
Connector type2 RJ45 (on the control block) for Ethernet IP/Modbus TCP 1 RJ45 (on the control block) for Modbus serial
Current262 A normal duty 234 A heavy duty
Frequency50 Hz +/- 5 %
IP ratingIP31
Temp storage max50 °C
Temp storage min0 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature0...50 °C
Pollution degree2 conforming to IEC 61800-5-1
Depth1500 mm
Width3560 mm
Height2751 mm
Operating temperature0...40 °C 40...50 °C with derating factor -25...70 °C during transport

Product details

1200 kW drive with 18-pulse rectifier

The ATV6000C150A3333NA3 is a floor-standing AC drive from the Altivar Process ATV6000 range, rated for 1200 kW normal duty and 1070 kW heavy duty at 480 V. It uses an 18-pulse diode rectifier bridge on the input and multilevel IGBT inverter cells on the output, keeping line-side harmonics below 3% THDI per IEEE 519-1992 without an external filter. Power factor sits at 0.96, and the drive handles synchronous, asynchronous, and permanent magnet motors. The enclosure measures 3560 mm wide by 1500 mm deep by 2751 mm high — plan the floor space and access clearance accordingly.

Control, I/O, and fieldbus slots

The drive carries a 10-inch LCD touchscreen HMI, configurable relay outputs (R1 fault NO/NC, R2 and R3 sequence NO), 8 programmable digital inputs (DI7/DI8 accept up to 30 kHz pulse input), and configurable analogue I/O (0–10 V or 0–20 mA). Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT communication modules; Slot B takes encoder interfaces (digital 5/12 V, analog, resolver, or HTL). The control circuit can be fed from 100–240 V AC (47–63 Hz) or 120–370 V DC; the auxiliary power supply for the cooling fan is 400 V AC ±10%. Electrical isolation between power and control is standard, with pollution degree 2 per IEC 61800-5-1.

MPN