Skip to main content
Schneider Electric ATV6000C200A2424ND — AC Drive (VFD) 480V

Schneider ATV6000C200A2424ND AC Drive, 1600 kW, 2000 kVA

MPNATV6000C200A2424ND
Active

Schneider Electric Altivar Process ATV6000, ATV6000C200A2424ND, AC Drive (VFD) 480V, 3-phase, 1600 kW normal duty, 2000 kVA, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6000C200A2424ND — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV6000
Product range / familyAltivar Process ATV6000

Power & Output

ATV6000C200A2424ND — Power & Output
ParameterValue
Motor power (kW)1360.0 kW heavy duty 1600.0 kW normal duty
Continuous output current392.0 A heavy duty 460.4 A normal duty
Max. transient current588.0 A 3 s heavy duty) 552.4 A 3 s normal duty)
Apparent power2000 kVA

Input / Supply

ATV6000C200A2424ND — Input / Supply
ParameterValue
Rated supply voltage range2.4 kV +/- 10 %
Input line current408.0 A heavy duty 552.4 A normal duty
Internal/auxiliary suppliesInternal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 %

Control & Performance

ATV6000C200A2424ND — Control & Performance
ParameterValue
Output frequency range0.1...120 Hz
Asynchronous motor control modesClosed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor

Protection & EMC

ATV6000C200A2424ND — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated IEC 61800-3 category C3 control Integrated IEC 61800-3 category C4 Power
Protection functionsLine supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overvoltages on the DC bus drive Thermal overload for transformer drive Cabinet overheating drive Overcurrent drive Overload drive Short-circuit protection drive IGBT for each cell drive Thermal protection motor Motor phase break motor Motor earth fault motor Break on the control circuit drive Fan monitoring drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6

Mechanical & Cooling

ATV6000C200A2424ND — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 conforming to IEC 60529
Acoustic noise level90.3 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure

Environmental

ATV6000C200A2424ND — Environmental
ParameterValue
Operating ambient temperature32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport
Operating altitude3280.84...6561.68 ft (1000...2000 m) with derating factor
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature32...122 °F (0...50 °C)
Pollution degree2 IEC 61800-5-1

Approvals

ATV6000C200A2424ND — Approvals
ParameterValue
Certifications & markingCULus CE UKCA
Standards complianceIEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076 UL 347A

Communication

ATV6000C200A2424ND — Communication
ParameterValue
Communication protocolsEthernet IP/Modbus TCP

Product details

Active production, floor-standing medium-voltage drive

The ATV6000C200A2424ND: It is a floor-standing enclosure drive (not panel-mount), part of the Altivar Process ATV6000 series, rated for 1600 kW normal duty / 1360 kW heavy duty motor power with 2000 kVA apparent power.

Line current and harmonic performance

Line current is 552.4 A normal duty, 408.0 A heavy duty — these are the numbers for sizing upstream cables and protection. The 54-pulse diode rectifier bridge keeps input current THDI below 3% per IEEE 519-1992, so external harmonic filters are not required for most utility compliance. Power factor is 0.96, reducing the need for power-factor correction capacitors at the service entrance.

Regulatory and standards coverage

Marked cULus, CE, UKCA — accepted for North American, EU, and UK installations without additional certification work. Compliant with IEC 61800-3 (EMC), IEC 61800-4, IEC 61800-5-1 (safety), and UL 347A — covers the drive system, transformer, and cells as a listed assembly.

Control and I/O complement

The drive ships with a 10-inch LCD touchscreen HMI, 8 programmable digital inputs (two configurable as pulse inputs up to 30 kHz), 3 relay outputs, configurable analog I/O, and dual RJ45 ports for Ethernet IP/Modbus TCP and Modbus serial. Option card slots (Slot A, Slot B) accept communication modules for Profibus DP, PROFINET, DeviceNet, CANopen, EtherCAT, plus encoder interface modules (digital 5/12 V, analog, resolver, HTL) and I/O extension.

Frequently asked questions

What compliance documentation does Schneider Electric provide for ATV6000C200A2424ND?

The drive carries cULus, CE, and UKCA markings and complies with IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEEE 519, and UL 347A. Documentation includes the standards listed on the nameplate.

MPN
ATV6000C200A2424ND