Skip to main content
Schneider Electric ATV6000C308A4242ND

Schneider ATV6000C308A4242ND VFD, 1970 kW HD, 24-pulse

MPN ATV6000C308A4242ND
Active

Schneider Electric Altivar Process ATV6000, ATV6000C308A4242ND, 3-phase, 1970 kW heavy duty / 2460 kW normal duty motor power, 24-pulse diode rectifier, floor-standing enclosure.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6000C308A4242ND specifications
ParameterValue
Input type24 pulse diode rectifier bridge
Display type10 inch LCD touch screen multi-language
Connector type2 RJ45 on the control block)Ethernet IP/Modbus TCP 1 RJ45 on the control block)Modbus serial
Current341 A heavy duty 428 A normal duty
Frequency50 Hz +/- 5 %
Phases3-phase
IP ratingIP31
Temp storage max50 °C
Temp storage min0 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature32...122 °F (0...50 °C)
Pollution degreePollution degree 2
Depth63.0 in (1600.0 mm)
Width199.2 in (5060.0 mm)
Height108.3 in (2751.0 mm)
Operating temperature32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport

Product details

The Schneider ATV6000C308A4242ND is a medium-voltage variable frequency drive from the Altivar Process ATV6000 series, built for large induction, synchronous, and permanent magnet motors. It delivers 1970 kW in heavy-duty service or 2460 kW in normal duty, fed through a 24-pulse diode rectifier that holds input current THDi under 3% per IEEE 519-1992 without external filtering.

This drive ships in a floor-standing enclosure measuring 63.0 in deep by 199.2 in wide by 108.3 in tall (1600 x 5060 x 2751 mm). Cable entry is at the bottom; forced convection cooling is built in. Plan for a plinth and clearance around the enclosure for service access. The cabinet includes the phase-shifting transformer, power cells, cooling fans, and a 10-inch LCD touch screen HMI.

Input and Output

Line current is 341 A heavy duty and 428 A normal duty; apparent power is 3080 kVA. The IGBT inverter uses multilevel PWM to generate output voltage up to the supply voltage level. The control circuit accepts 100–240 V AC 47–63 Hz or 120–370 V DC, and a separate 400 V AC supply powers the cooling fan (7 kVA). A 1 kVA auxiliary supply at 230 V AC handles the control cabinet.

MPN
ATV6000C308A4242ND