Skip to main content
Schneider Electric ATV6000C328A3333NA3 — AC Drive (VFD) 480V

Schneider ATV6000C328A3333NA3 VFD, 2620 kW, 3280 kVA, 480V

MPNATV6000C328A3333NA3
Active

Schneider Electric Altivar Process ATV6000 AC Drive, ATV6000C328A3333NA3, 2620 kW normal duty / 2100 kW heavy duty, 3280 kVA, 480 V class, 18-pulse diode rectifier, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6000C328A3333NA3 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV6000
Product range / familyAltivar Process ATV6000

Power & Output

ATV6000C328A3333NA3 — Power & Output
ParameterValue
Motor power (kW)2620 kW for normal duty 2100 kW for heavy duty
Continuous output current550 A normal duty 440 A heavy duty
Max. transient current825 A during 3 s (normal duty) 825 A during 3 s (heavy duty)
Apparent power3280 kVA

Input / Supply

ATV6000C328A3333NA3 — Input / Supply
ParameterValue
Rated supply voltage range3.3 kV +/- 10 %
Input line current574 A normal duty 458 A heavy duty
Network number of phases3 phases
Internal/auxiliary suppliesInternal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 26 kVA

Control & Performance

ATV6000C328A3333NA3 — Control & Performance
ParameterValue
Output frequency range0.1...120 Hz
Asynchronous motor control modesClosed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor

Protection & EMC

ATV6000C328A3333NA3 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated conforming to IEC 61800-3 category C3 control Integrated conforming to IEC 61800-3 category C4 power
Protection functionsLine supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overvoltages on the DC bus: drive Thermal overload for transformer: drive Cabinet overheating: drive Overcurrent: drive Overload: drive Short-circuit protection: drive IGBT for each cell: drive Thermal protection: motor Motor phase break: motor Motor earth fault: motor Break on the control circuit: drive Fan monitoring: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV6000C328A3333NA3 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 conforming to IEC 60529
Acoustic noise level85 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure

Environmental

ATV6000C328A3333NA3 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C with derating factor -25...70 °C during transport
Operating altitude1000...2000 m with derating factor
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature0...50 °C
Pollution degree2 conforming to IEC 61800-5-1

Approvals

ATV6000C328A3333NA3 — Approvals
ParameterValue
Certifications & markingEAC CE
Standards complianceIEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076

Communication

ATV6000C328A3333NA3 — Communication
ParameterValue
Communication protocolsEthernet IP/Modbus TCP Modbus serial

Product details

Power stage and motor ratings

The ATV6000C328A3333NA3: Rated 2620 kW for normal duty and 2100 kW for heavy duty, with an apparent power of 3280 kVA. The line current draw is 574 A at normal duty, 458 A at heavy duty — these numbers govern the incoming cable and transformer sizing, not the motor FLA alone. The 18-pulse diode rectifier input keeps total harmonic current distortion below 3 % per IEEE 519-1992, which means you can often skip an external harmonic filter on a dedicated transformer. Power factor is 0.96.

Physical footprint and enclosure

This is a floor-standing enclosure, not a wall-mount drive. Dimensions: 5760 mm wide, 1700 mm deep, 2791 mm high. Plan for a dedicated electrical room bay with front and rear access for cable entry from the bottom and forced-convection cooling airflow. Sound pressure level is 85 dB — hearing protection zones apply around the drive during operation.

Controls, communications, and I/O

The standard HMI is a 10-inch LCD colour touchscreen with multi-language support. Communication slots accept Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT on Slot A; encoder feedback modules (digital, analog, resolver, HTL) on Slot B. Built-in Ethernet IP/Modbus TCP on two RJ45 ports plus one dedicated Modbus serial RJ45. The 8 digital inputs include two programmable as pulse inputs up to 30 kHz; analogue inputs are configurable 0–10 V or 0–20 mA. Three configurable relay outputs (one NO/NC fault relay, two NO sequence relays) plus configurable analogue outputs (0–10 V / 0–20 mA).

Protection suite and compliance

The drive monitors line overvoltage, undervoltage, phase loss, DC bus overvoltage, transformer thermal overload, cabinet overtemperature, overcurrent, overload, short-circuit, and motor earth fault. Each IGBT power cell has its own thermal protection. Marked EAC and CE. Designed to IEC 61800-3 (EMC), IEC 61800-4, IEC 61800-5-1 (safety), and IEC 60529 (enclosure). Pollution degree 2 per IEC 61800-5-1. Integrated EMC filter meets category C3 on the control side and C4 on the power side.

Frequently asked questions

What is the physical size of this drive?

The floor-standing enclosure measures 5760 mm wide by 1700 mm deep by 2791 mm high. Cable entry is from the bottom. Plan for a dedicated electrical room footprint with front and rear access.

What fieldbus options are available?

Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), or EtherCAT. Two RJ45 ports on the control block support Ethernet IP/Modbus TCP, plus one dedicated Modbus serial RJ45 port.

MPN
ATV6000C328A3333NA3