Skip to main content
Schneider Electric ATV6000C425A6666ND — AC Drive (VFD) 480V

Schneider ATV6000C425A6666ND Altivar Process ATV6000, 4250 k

MPNATV6000C425A6666ND
Active

Schneider Electric Altivar Process ATV6000, ATV6000C425A6666ND, 4250 kVA, 3-phase, 30-pulse diode rectifier, IGBT multilevel PWM output.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6000C425A6666ND — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV6000
Product range / familyAltivar Process ATV6000

Power & Output

ATV6000C425A6666ND — Power & Output
ParameterValue
Motor power (kW)3400 kW normal duty 3130 kW heavy duty
Continuous output current356 A normal duty 328 A heavy duty
Max. transient current534 A 3 s normal duty) 615 A 3 s heavy duty)
Apparent power4250 kVA

Input / Supply

ATV6000C425A6666ND — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current341 A heavy duty 372 A normal duty
Internal/auxiliary suppliesInternal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 18 kVA

Control & Performance

ATV6000C425A6666ND — Control & Performance
ParameterValue
Output frequency range0.1...120 Hz
Asynchronous motor control modesClosed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor

Protection & EMC

ATV6000C425A6666ND — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated IEC 61800-3 category C3 control Integrated IEC 61800-3 category C4 Power
Protection functionsLine supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overvoltages on the DC bus drive Thermal overload for transformer drive Cabinet overheating drive Overcurrent drive Overload drive Short-circuit protection drive IGBT for each cell drive Thermal protection motor Motor phase break motor Motor earth fault motor Break on the control circuit drive Fan monitoring drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)31.5 kA 150 ms

Mechanical & Cooling

ATV6000C425A6666ND — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 conforming to IEC 60529
Acoustic noise level83 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure

Environmental

ATV6000C425A6666ND — Environmental
ParameterValue
Operating ambient temperature32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport
Operating altitude3280.84...6561.68 ft (1000...2000 m) with derating factor
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature32...122 °F (0...50 °C)
Pollution degree2 IEC 61800-5-1

Approvals

ATV6000C425A6666ND — Approvals
ParameterValue
Certifications & markingCULus CE UKCA
Standards complianceIEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076 UL 347A

Communication

ATV6000C425A6666ND — Communication
ParameterValue
Communication protocolsEthernet IP/Modbus TCP

Product details

The Schneider Electric ATV6000C425A6666ND is an Altivar Process ATV6000 medium-voltage drive. It delivers 4250 kVA apparent power, rated for 3400 kW normal duty and 3130 kW heavy duty on asynchronous, permanent magnet, or synchronous motors. Line current draws 341 A heavy duty, 372 A normal duty. The 30-pulse diode rectifier bridge keeps input THDI below 3 % per IEEE 519-1992, so you can skip external harmonic filters on most grids.

Output uses IGBT inverter cells in a multilevel PWM topology, which gives clean voltage waveforms and lower motor stress than two-level drives. Output voltage equals or tracks the supply voltage. Integrated EMC filters cover IEC 61800-3 category C3 on the control side and C4 on the power side. Electrical isolation between power and control circuits is standard. The drive is floor-standing, 66.9 in deep, 234.6 in wide, 109.9 in high. Plan for bottom cable entry and forced convection cooling — the fan supply is 400 V AC at 18 kVA.

Frequently asked questions

What are the motor power ratings?

3400 kW normal duty, 3130 kW heavy duty.

What compliance markings does it carry?

CULus, CE, and UKCA. It meets IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, EN/IEC 60076, and UL 347A.

MPN