Skip to main content
Schneider Electric ATV6000D500A1111NA3

Schneider ATV6000D500A1111NA3 AC Drive, 400 kW, 500 kVA

MPN ATV6000D500A1111NA3
Active

Schneider Electric Altivar Process ATV6000, ATV6000D500A1111NA3, AC Drive (VFD) 480V, 400 kW normal duty / 380 kW heavy duty, 500 kVA apparent power, floor-standing enclosure, 54-pulse diode rectifier.

Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV6000D500A1111NA3 specifications
ParameterValue
Input type54 pulse diode rectifier bridge
Display type10 inch LCD touch screen multi-language
Connector type2 RJ45 (on the control block) for Ethernet IP/Modbus TCP 1 RJ45 (on the control block) for Modbus serial
Current26.3 A normal duty 25 A heavy duty
Frequency50 Hz +/- 5 %
IP ratingIP31
Temp storage max50 °C
Temp storage min0 °C
Temp operating max60 °C
Temp operating min1.2 °C
Storage temperature0...50 °C
Pollution degree2 conforming to IEC 61800-5-1
Depth1600 mm
Width3860 mm
Height2751 mm
Operating temperature0...40 °C 40...50 °C with derating factor -25...70 °C during transport

Product details

400 kW drive in a floor-standing enclosure

The ATV6000D500A1111NA3 is a Schneider Electric Altivar Process ATV6000 AC drive rated for 400 kW normal duty and 380 kW heavy duty motor power, with an apparent power rating of 500 kVA. It ships as a complete floor-standing enclosure assembly — 2751 mm high, 3860 mm wide, 1600 mm deep — integrating the phase-shifting transformer, power cells, cooling fans, and HMI.

Line-side harmonics and input topology

A 54-pulse diode rectifier bridge feeds the DC bus, keeping total harmonic current distortion below 3 % per IEEE 519:1992 without an external filter. The power factor sits at 0.96, and the integrated EMC filter meets IEC 61800-3 category C3 on the control side and C4 on the power side.

Motor types and output stage

The output uses IGBT inverter cells in a multilevel PWM topology, suitable for asynchronous, synchronous, and permanent magnet motors. Output voltage matches the supply voltage; the drive includes motor thermal protection, phase-loss detection, and earth-fault monitoring.

Control interfaces and expandability

The control block carries two RJ45 ports for Ethernet IP / Modbus TCP and one RJ45 for Modbus serial. Slot A accepts fieldbus option cards for Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT. Slot B supports encoder feedback modules (digital 5/12 V, analog, resolver, or HTL). Digital and analog I/O or relay extension modules fit either slot. The 10-inch LCD touch screen provides multi-language local control and monitoring.

Regulatory compliance and lifecycle

Marked EAC and CE, designed to IEC 61800-3, IEC 61800-4, IEC 61800-5-1, and IEC 60529. Pollution degree 2 per IEC 61800-5-1.

MPN
ATV6000D500A1111NA3