Schneider Electric ATV6000D570A6666ND — AC Drive (VFD) 480V

Schneider ATV6000D570A6666ND AC Drive, 450 kW ND, 480V

MPNATV6000D570A6666ND
Active

Schneider Electric Altivar Process ATV6000, AC Drive (VFD) 480V, 450 kW normal duty / 430 kW heavy duty, 30-pulse diode rectifier, floor-standing enclosure, 55.1 x 108.7 x 103.0 in.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6000D570A6666ND — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV6000
Product range / familyAltivar Process ATV6000

Power & Output

ATV6000D570A6666ND — Power & Output
ParameterValue
Motor power (kW)450 kW normal duty 430 kW heavy duty
Continuous output current47.1 A normal duty 45 A heavy duty
Max. transient current70.6 A 3 s normal duty) 84.4 A 3 s heavy duty)
Apparent power570 kVA

Input / Supply

ATV6000D570A6666ND — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current49.9 A normal duty 47 A heavy duty
Internal/auxiliary suppliesInternal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 7 kVA

Control & Performance

ATV6000D570A6666ND — Control & Performance
ParameterValue
Output frequency range0.1...120 Hz
Asynchronous motor control modesClosed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor

Protection & EMC

ATV6000D570A6666ND — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated IEC 61800-3 category C3 control Integrated IEC 61800-3 category C4 Power
Protection functionsLine supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overvoltages on the DC bus drive Thermal overload for transformer drive Cabinet overheating drive Overcurrent drive Overload drive Short-circuit protection drive IGBT for each cell drive Thermal protection motor Motor phase break motor Motor earth fault motor Break on the control circuit drive Fan monitoring drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)31.5 kA 150 ms

Mechanical & Cooling

ATV6000D570A6666ND — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 conforming to IEC 60529
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure

Environmental

ATV6000D570A6666ND — Environmental
ParameterValue
Operating ambient temperature32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport
Operating altitude3280.84...6561.68 ft (1000...2000 m) with derating factor
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature32...122 °F (0...50 °C)
Pollution degree2 IEC 61800-5-1

Approvals

ATV6000D570A6666ND — Approvals
ParameterValue
Certifications & markingCULus CE UKCA
Standards complianceIEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076 UL 347A

Communication

ATV6000D570A6666ND — Communication
ParameterValue
Communication protocolsEthernet IP/Modbus TCP

Product details

450 kW drive with <3% input harmonics

The Schneider Electric ATV6000D570A6666ND is a 480V-class AC drive from the Altivar Process ATV6000 family, rated 450 kW in normal duty and 430 kW in heavy duty. It uses a 30-pulse diode rectifier input stage that keeps total harmonic current distortion below 3% per IEEE 519-1992, eliminating the need for external harmonic filters on most installations. This is a large-footprint drive delivered in a floor-standing enclosure measuring 55.1 inches deep by 108.7 inches wide by 103.0 inches tall. The package includes the phase-shifting transformer, power cells, medium voltage arrestors, HMI, cooling fans, and plinth — it arrives as a complete drive system, not a bare chassis.

Active production with multi-protocol fieldbus

Communication flexibility is built in via Slot A and Slot B option card architecture. Slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), or EtherCAT modules. Slot B handles encoder interfaces (5/12 V digital, analog, resolver, HTL) and digital/analog I/O or output relay extension modules.

Compliance and installation context

The drive carries cULus, CE, and UKCA markings and complies with IEC 61800-3 (EMC categories C3 control / C4 power), IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, EN/IEC 60076, and UL 347A. Pollution degree 2 per IEC 61800-5-1 applies to the internal environment. Cable entry is at the bottom of the enclosure. The drive is forced-convection cooled and rated for 5% to 95% relative humidity without condensation. Operating altitude is 1000 to 2000 meters with derating. The 80 dB noise level means hearing protection is advisable in the equipment room.

Frequently asked questions

Where can I buy ATV6000D570A6666ND and how do I get a price?

This drive is sourced to order against the BOM through independent distribution.

What compliance documentation does Schneider Electric provide for ATV6000D570A6666ND?

The drive carries cULus, CE, and UKCA markings. It complies with IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, EN/IEC 60076, and UL 347A.

MPN