Skip to main content
Schneider Electric ATV6000D630A6666ND — AC Drive (VFD) 480V

Schneider ATV6000D630A6666ND AC Drive, 500 kW, 630 kVA, 480V

MPNATV6000D630A6666ND
Active

Schneider Electric Altivar Process ATV6000 AC drive, ATV6000D630A6666ND, 500 kW normal duty / 470 kW heavy duty, 630 kVA, 3-phase, floor-standing enclosure, 10-inch LCD touch screen.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6000D630A6666ND — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV6000
Product range / familyAltivar Process ATV6000

Power & Output

ATV6000D630A6666ND — Power & Output
ParameterValue
Motor power (kW)500 kW normal duty 470 kW heavy duty
Continuous output current52.3 A normal duty 50 A heavy duty
Max. transient current78.4 A 3 s normal duty) 93.8 A 3 s heavy duty)
Apparent power630 kVA

Input / Supply

ATV6000D630A6666ND — Input / Supply
ParameterValue
Rated supply voltage range6.6 kV +/- 10 %
Input line current55.2 A normal duty 52 A heavy duty
Internal/auxiliary suppliesInternal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 7 kVA

Control & Performance

ATV6000D630A6666ND — Control & Performance
ParameterValue
Output frequency range0.1...120 Hz
Asynchronous motor control modesClosed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor

Protection & EMC

ATV6000D630A6666ND — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated IEC 61800-3 category C3 control Integrated IEC 61800-3 category C4 Power
Protection functionsLine supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overvoltages on the DC bus drive Thermal overload for transformer drive Cabinet overheating drive Overcurrent drive Overload drive Short-circuit protection drive IGBT for each cell drive Thermal protection motor Motor phase break motor Motor earth fault motor Break on the control circuit drive Fan monitoring drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)31.5 kA 150 ms

Mechanical & Cooling

ATV6000D630A6666ND — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 conforming to IEC 60529
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure

Environmental

ATV6000D630A6666ND — Environmental
ParameterValue
Operating ambient temperature32...104 °F (0...40 °C) 104...122 °F (40...50 °C) with derating factor -13...158 °F (-25...70 °C) during transport
Operating altitude3280.84...6561.68 ft (1000...2000 m) with derating factor
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature32...122 °F (0...50 °C)
Pollution degree2 IEC 61800-5-1

Approvals

ATV6000D630A6666ND — Approvals
ParameterValue
Certifications & markingCULus CE UKCA
Standards complianceIEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076 UL 347A

Communication

ATV6000D630A6666ND — Communication
ParameterValue
Communication protocolsEthernet IP/Modbus TCP

Product details

630 kVA drive for medium-voltage motor control

The ATV6000D630A6666ND is a 630 kVA Altivar Process ATV6000 drive rated 500 kW normal duty and 470 kW heavy duty, using a 30-pulse diode rectifier front end and IGBT inverter cells with multilevel PWM output. Total harmonic current distortion is below 3% per IEEE 519-1992, and the power factor is 0.96 — the multi-pulse topology cleans the line without an external filter for most installations.

Floor-standing enclosure with integrated transformer

The drive ships in a floor-standing enclosure measuring 103.03 in high by 108.7 in wide by 55.1 in deep, with bottom cable entry and forced-convection cooling. Provided equipment includes the phase-shifting transformer, power cells, cooling fans, plinth, medium-voltage arrestors, and the HMI — the enclosure is a complete assembly, not a bare drive chassis.

10-inch touch screen and multi-protocol comms

The HMI is a 10-inch LCD multi-language touch screen; the control block carries two RJ45 ports for Ethernet IP/Modbus TCP and one for Modbus serial, plus slot A supports Profibus DP V1, PROFINET, DeviceNet, CANopen, or EtherCAT option cards. Slot B accepts encoder interface modules (digital 5/12 V, analog, resolver, HTL) and I/O or relay extension modules — the drive can be configured for closed-loop speed or position control without an external controller.

Protection coverage and compliance

Protection includes line supply overvoltage/undervoltage/phase loss, DC bus overvoltage, cabinet overheating, overcurrent, overload, short-circuit, motor thermal, motor phase break, motor earth fault, and fan monitoring. Marked CULus, CE, and UKCA; designed to IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, EN/IEC 60076, and UL 347A. Pollution degree 2 per IEC 61800-5-1.

Frequently asked questions

What is the ATV6000D630A6666ND used for?

It is a medium-voltage AC drive for asynchronous, synchronous, and permanent magnet motors up to 500 kW normal duty or 470 kW heavy duty, typically installed in pump, fan, compressor, and conveyor applications requiring low line harmonics.

What compliance documentation does Schneider provide for this drive?

The drive carries CULus, CE, and UKCA markings and is designed to IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, EN/IEC 60076, and UL 347A standards.

MPN
ATV6000D630A6666ND