Skip to main content
Schneider Electric ATV6000D890A3333NA3 — AC Drive (VFD) 480V

Schneider ATV6000D890A3333NA3 Altivar Process drive, 890 kVA

MPNATV6000D890A3333NA3
Active

Schneider Electric Altivar Process ATV6000, ATV6000D890A3333NA3, medium-voltage variable speed drive, 890 kVA, 570 kW heavy duty / 710 kW normal duty, 18-pulse rectifier, floor-standing enclosure.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6000D890A3333NA3 — Identification
ParameterValue
Product typeMedium voltage variable speed drive
Device short nameATV6000
Product range / familyAltivar Process ATV6000

Power & Output

ATV6000D890A3333NA3 — Power & Output
ParameterValue
Motor power (kW)570 kW for heavy duty 710 kW for normal duty
Continuous output current120 A heavy duty 150 A normal duty
Max. transient current225 A during 3 s (heavy duty) 225 A during 3 s (normal duty)
Apparent power890 kVA

Input / Supply

ATV6000D890A3333NA3 — Input / Supply
ParameterValue
Rated supply voltage range3.3 kV +/- 10 %
Input line current125 A heavy duty 156 A normal duty
Network number of phases3 phases
Internal/auxiliary suppliesInternal supply for digital inputs and PoE 24 V DC 21...27 V, Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, External supply for digital inputs 24 V DC 19...30 V External supply for control circuit 100...240 V AC 47...63 Hz External supply for control circuit 120...370 V DC +/- 10 % 1 kVA Auxiliary power supply 230 V AC +/- 10 % External supply for cooling fan 400 V AC +/- 10 % 7 kVA

Control & Performance

ATV6000D890A3333NA3 — Control & Performance
ParameterValue
Output frequency range0.1...120 Hz
Asynchronous motor control modesClosed loop vector control U/F vector control Energy saving control Vector control with slip compensation in open loop
Synchronous motor control modesPermanent magnet control in open loop Permanent magnet control in close loop Line start permanent magnet motor

Protection & EMC

ATV6000D890A3333NA3 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated conforming to IEC 61800-3 category C3 control Integrated conforming to IEC 61800-3 category C4 power
Protection functionsLine supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overvoltages on the DC bus: drive Thermal overload for transformer: drive Cabinet overheating: drive Overcurrent: drive Overload: drive Short-circuit protection: drive IGBT for each cell: drive Thermal protection: motor Motor phase break: motor Motor earth fault: motor Break on the control circuit: drive Fan monitoring: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)31.5 kA for 150 ms

Mechanical & Cooling

ATV6000D890A3333NA3 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP31 conforming to IEC 60529
Acoustic noise level80 dB
Cooling methodForced convection
Assembly / installation styleIn floor-standing enclosure

Environmental

ATV6000D890A3333NA3 — Environmental
ParameterValue
Operating ambient temperature0...40 °C 40...50 °C with derating factor -25...70 °C during transport
Operating altitude1000...2000 m with derating factor
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature0...50 °C
Pollution degree2 conforming to IEC 61800-5-1

Approvals

ATV6000D890A3333NA3 — Approvals
ParameterValue
Certifications & markingCE EAC
Standards complianceIEC 61800-3 EN/IEC 61800-4 IEC 61800-5-1 IEC 60529 IEEE 519:1992 EN/IEC 60076

Communication

ATV6000D890A3333NA3 — Communication
ParameterValue
Communication protocolsModbus serial Ethernet IP/Modbus TCP

Product details

The Schneider Electric ATV6000D890A3333NA3 is a medium-voltage Altivar Process drive rated for 890 kVA apparent power, delivering 570 kW in heavy-duty service or 710 kW in normal-duty service. The 18-pulse diode rectifier input keeps line-side THDI below 3% per IEEE 519-1992, so it meets harmonic compliance without an external filter in most industrial grids. Line current draws 125 A heavy duty, 156 A normal duty. The floor-standing enclosure measures 2760 mm wide by 2641 mm high by 1400 mm deep — that footprint governs the substation floor plan and cable entry routing (bottom entry only). Forced-convection cooling with integrated fans; noise level is 80 dB, so ear protection zones apply near the cabinet.

Integration and control interfaces

The drive ships with a 10-inch LCD touchscreen HMI, configurable relay outputs (three), and programmable digital inputs (eight, two configurable as pulse inputs up to 30 kHz). Analog I/O covers 0–10 V and 0–20 mA on both inputs and outputs, 12-bit resolution on inputs. Communication slot A accepts Profibus DP V1, PROFINET, DeviceNet, CANopen (RJ45, SUB-D 9, or screw terminals), or EtherCAT modules. Slot B handles encoder interfaces (5/12 V digital, analog, resolver, HTL). A digital/analog I/O extension module or output relay extension module fits either slot. Control circuit supply can be 100–240 V AC 47–63 Hz or 120–370 V DC; auxiliary power is 230 V AC, and the cooling fan supply is 400 V AC. Electrical isolation between power and control circuits is standard. The integrated EMC filter meets IEC 61800-3 category C3 on the control side and C4 on the power side.

Frequently asked questions

What compliance documentation does this drive carry?

CE and EAC marking. Standards include IEC 61800-3, IEC 61800-4, IEC 61800-5-1, IEC 60529, IEEE 519:1992, and EN/IEC 60076.

MPN
ATV6000D890A3333NA3