Drive ratings and power quality
The ATV6000D890A4242ND: Rated 710 kW normal duty and 680 kW heavy duty, with a corresponding line current of 124 A normal duty and 118 A heavy duty — the heavy-duty figure governs continuous operation on a constant-torque load like a conveyor or extruder. The 24-pulse diode rectifier front end keeps input current THDI below 3 % per IEEE 519-1992, which means no external harmonic filter is needed for most utility compliance scenarios. Power factor sits at 96 %, apparent power is 890 kVA, and total power losses run 30.9 kW normal duty / 29.7 kW heavy duty — the loss figure drives the ventilation requirement of the room the cabinet sits in.
Physical footprint and included hardware
The drive ships in a floor-standing enclosure measuring 55.1 in deep by 128.3 in wide by 102.4 in high — this is a dedicated drive room or large electrical-room footprint, not a wall-mount. Included in the package: phase-shifting transformer, power cells, cooling fans, medium voltage arrestors, plinth, and a 10-inch LCD touch-screen HMI — the transformer and cells are integral to the multilevel IGBT inverter topology.