The ATV600SYSTEM is a Schneider Electric Altivar Process ATV600 variable speed drive supplied as a complete floor-standing enclosure — the 'full ETO' variant means it ships with the enclosure, main switch, line choke, dv/dt filter choke, terminal blocks for main supply and motor, and the graphical operating panel already wired in. It is designed for industrial applications requiring a packaged drive solution that arrives ready for power and motor connections, not a component you build into a panel. Supply voltage covers 380...415 V through 690 V (all with -10...6 % tolerance), three-phase, 50/60 Hz ±5 %. Protection is IP23 as standard (conforming to IEC 61800-5-1) and IP54 where the enclosure seal is upgraded — the listing carries both, so verify which your site requires. Forced convection cooling keeps the drive within its -10...50 °C operating band (derated above 40 °C, and requiring enclosure heating below 0 °C).
The wide voltage range is the headline: 380 V to 690 V on one SKU simplifies spares stocking for a site with mixed supply voltages. But the altitude derating matters if your installation is above 1000 m — 1 % current derating per 100 m up to 2000 m, and further derating above that for TT/TN/IT earthing systems. The EMC immunity test levels (level 3 for electrostatic discharge and radiated RF, level 4 for fast transients and surges) place it in a heavy industrial environment without external filtering for most cases. Motor control profiles include constant torque, variable torque, optimized torque mode for asynchronous motors, and permanent magnet synchronous motor control. That covers pumps, fans, conveyors, and increasingly common PM motor retrofits on one drive platform.
Floor-standing enclosure, compact version, with top and bottom cable entry. Operating position is vertical ±10°. The enclosure colour is light grey (RAL 7035), and the assembly is designed for industrial floor mounting — not wall-mount. Provided equipment includes the dv/dt filter choke, which protects motor insulation on longer cable runs, and the line choke for harmonic mitigation. Vibration resistance meets 3M3 per IEC 60721-3-3 (0.6 gn at 10-200 Hz, 1.5 mm peak-to-peak at 3-10 Hz). Shock resistance is 4 gn for 11 ms, 3M2. That is sufficient for general industrial floor vibration but not for direct mounting on a reciprocating compressor skid without isolation mounts. Environmental classification includes chemical pollution resistance class 3C3, dust pollution resistance 3S3, and humidity resistance 3K3 (5...95 % RH without condensation). Storage temperature is -25...70 °C.