Skip to main content
Schneider Electric ATV630C25N4US — AC Drive (VFD) 480V

ATV630C25N4US Schneider Altivar Process VSD, 481 A ND

MPNATV630C25N4US
Active

Schneider Electric Altivar Process ATV630, ATV630C25N4US, variable speed drive, 380-480 V, 481 A normal duty, 250 kW.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV630C25N4US — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV630
Product range / familyAltivar Process ATV600
ATV630C25N4US — Power & Output
ParameterValue
Motor power (kW)250 kW normal duty) 220 kW heavy duty)
Continuous output current481 A 2.5 kHz normal duty 387 A 2.5 kHz heavy duty
ATV630C25N4US — Input / Supply
ParameterValue
Rated supply voltage range380...480 V
Input line current451 A 380 V normal duty) 366 A 480 V normal duty) 365 A 380 V heavy duty) 301 A 480 V heavy duty)
ATV630C25N4US — Control & Performance
ParameterValue
Output frequency range0.1...500 Hz
ATV630C25N4US — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 164.04 ft (50 m) IEC 61800-3 category C3
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
ATV630C25N4US — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00IEC 61800-5-1 IP00IEC 60529 IP21 with kit VW3A9113)IEC 61800-5-1 IP21 with kit VW3A9113)IEC 60529
Acoustic noise level76 dB
Cooling methodForced convection
ATV630C25N4US — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) (without derating) 104...140 °F (40...60 °C) (with derating factor)
Operating altitude3280.84...9842.52 ft (1000...3000 m) with current derating 1 % per 100 m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-13...158 °F (-25...70 °C)
Pollution degree2
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV630C25N4US — Approvals
ParameterValue
Certifications & markingCE
Standards complianceUL 508C IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV630C25N4US — Communication
ParameterValue
Communication protocolsModbus TCP Modbus serial Ethernet

Product details

The ATV630C25N4US is a 380-480 V variable speed drive from the Altivar Process ATV600 series, rated for 481 A continuous output in normal duty and 387 A in heavy duty, covering motors up to 250 kW (normal duty) or 220 kW (heavy duty). It handles both asynchronous and synchronous motors, with a 0.1-500 Hz output range.

Duty selection and real-world headroom

Line current draw differs by supply voltage and duty: 451 A at 380 V normal duty, 366 A at 480 V normal duty; heavy duty drops to 365 A (380 V) and 301 A (480 V). The 400 hp normal duty rating translates to 300 hp in heavy duty — a 25% derating that matters if your application cycles near full load. Always size cabling and upstream protection for the normal-duty line current at your actual supply voltage.

EMC and compliance package

An integrated EMC filter covers 50 m cable runs to IEC 61800-3 category C3 (second environment). For first-environment installations (residential or light commercial), an external filter is needed. The drive also carries UL 508C, IEC 61800-5-1, and pollution degree 2 rating. Total harmonic current distortion stays below 48% at full load per IEC 61000-3-12.

Mounting, cooling, and environmental limits

Wall-mount only, vertical within ±10°. IP00 as delivered; a VW3A9113 kit adds IP21. Forced convection moves 1260 m³/h of cooling air — plan for at least that clearance above and below. Vibration tolerance is 1.5 mm p-p (2-13 Hz) and 1 gn (13-200 Hz); shock rated at 15 gn, 11 ms. Operating altitude up to 1000 m without derating; above that, derate 1% per 100 m.

Safety and communication options

Safe Torque Off (STO) is built in to SIL 3. Slot A accepts a wide range of fieldbus modules: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen, Ethernet IP, BACnet MS/TP, or Ethernet Powerlink. The drive also includes Modbus TCP and Modbus serial as standard. Eight digital inputs, two configurable as high-speed pulse (up to 30 kHz).

Frequently asked questions

What is the CE marking status?

The drive carries CE marking, along with UL 508C, IEC 61800-5-1, and a range of IEC standards for EMC, safety, and environmental conditions.

What is the variant listed as?

It is listed as a Standard version (variant: Standard version), meaning no special factory options beyond the base configuration.

What compliance documentation is available?

The drive complies with UL 508C, IEC 61800-3 (environment categories C2/C3), IEC 61800-5-1, IEC 61508, IEC 13849-1, and IEC 61000-3-12, with an integrated EMC filter for category C3.

MPN
ATV630C25N4US