Skip to main content
Schneider Electric ATV630D22N4 — AC Drive (VFD) 480V

Schneider Electric ATV630D22N4 Altivar Process VFD, 22 kW

MPNATV630D22N4
Active

Schneider Electric Altivar Process ATV630D22N4 variable speed drive, 22 kW normal duty / 18.5 kW heavy duty, 380-480 V, 46.3 A continuous output, IP21, wall mount, standard version.

$1,280.00Ref. price · indicative, final on quote
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV630D22N4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV630
Product range / familyAltivar Process ATV600
ATV630D22N4 — Power & Output
ParameterValue
Motor power (kW)22 kW normal duty) 18.5 kW heavy duty)
Continuous output current46.3 A 4 kHz normal duty 39.2 A 4 kHz heavy duty
ATV630D22N4 — Input / Supply
ParameterValue
Rated supply voltage range380...480 V
Input line current39.6 A 380 V normal duty) 34.4 A 480 V normal duty) 34.1 A 380 V heavy duty) 29.9 A 480 V heavy duty)
ATV630D22N4 — Control & Performance
ParameterValue
Output frequency range0.1...500 Hz
ATV630D22N4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 164.04 ft (50 m) IEC 61800-3 category C2 Integrated 492.1 ft (150 m) IEC 61800-3 category C3
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
ATV630D22N4 — Mechanical & Cooling
ParameterValue
Degree of protection (IP)UL type 1 UL 508C
IP degree of protectionIP21IEC 61800-5-1 IP21IEC 60529
Acoustic noise level59.5 dB
Cooling methodForced convection
ATV630D22N4 — Environmental
ParameterValue
Operating ambient temperature5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV630D22N4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceUL 508C IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV630D22N4 — Communication
ParameterValue
Communication protocolsModbus TCP Ethernet Modbus serial

Product details

The ATV630D22N4 is a 22 kW normal-duty / 18.5 kW heavy-duty VFD from the Altivar Process ATV600 series, designed for asynchronous and synchronous motor control in process applications like pumps, fans, and conveyors. Rated supply voltage is 380-480 V, 50/60 Hz, with a continuous output current of 46.3 A at 4 kHz carrier in normal duty, derating to 39.2 A in heavy duty — the heavy-duty figure governs motor starting and overload cycles. Line current at 480 V normal duty is 34.4 A — this is the figure to use for upstream breaker and contactor sizing, not the 46.3 A output rating. The integrated EMC filter covers 50 m for C2 (restricted distribution) and 150 m for C3 (industrial) environments per IEC 61800-3, eliminating the need for an external filter in most panel builds.

Safety and compliance — STO and standards stack

CE marking is present, confirming conformity with applicable EU directives for placement on the European market.

Field integration — mounting, cooling, and environment

Wall-mount design with IP21 protection (IEC 60529) and UL Type 1 enclosure — suitable for indoor panel installation where drip protection is sufficient, but not for washdown or outdoor use. Forced convection cooling moves 215 m³/h of air, with a noise level of 59.5 dB — audible in a quiet control room but typical for a drive of this power class. Operating altitude derating starts above 1000 m at 1 % per 100 m, and the drive must be mounted vertically within ±10 degrees — both points matter for installation in elevated plant areas or non-standard orientations. Vibration resistance is 1.5 mm peak-to-peak at 2-13 Hz and 1 g at 13-200 Hz per IEC 60068-2-6, with shock resistance of 15 g for 11 ms — tough enough for most industrial machinery without additional isolation.

Sourcing and lifecycle — active production, quoted to order

No stock-holding claim — quoted per RFQ. The standard version means no conformal coating or severe-environment options — if the installation sees condensation or conductive dust, consider the coated variant of the same drive family.

Frequently asked questions

What are the key ratings for the ATV630D22N4?

The drive is rated 22 kW normal duty / 18.5 kW heavy duty at 380-480 V supply, with 46.3 A continuous output at 4 kHz carrier in normal duty and 39.2 A in heavy duty. Line current at 480 V normal duty is 34.4 A. STO SIL 3 is standard.

MPN
ATV630D22N4