Skip to main content
Schneider Electric ATV630D45N4Z — AC Drive (VFD) 480V

Schneider ATV630D45N4Z Altivar Process Drive, 45kW

MPNATV630D45N4Z
Active

Schneider Electric Altivar Process ATV630, variable speed drive, 380-480V, 45 kW normal duty, 88 A continuous, IP20, STO SIL3.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV630D45N4Z — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV630
Product range / familyAltivar Process ATV600
ATV630D45N4Z — Power & Output
ParameterValue
Motor power (kW)45 kW normal duty) 37 kW heavy duty)
Continuous output current88 A 4 kHz normal duty 74.5 A 4 kHz heavy duty
ATV630D45N4Z — Input / Supply
ParameterValue
Rated supply voltage range380...480 V
Input line current79.8 A 380 V normal duty) 69.1 A 480 V normal duty) 67.1 A 380 V heavy duty) 59 A 480 V heavy duty)
ATV630D45N4Z — Control & Performance
ParameterValue
Output frequency range0.1...500 Hz
ATV630D45N4Z — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 32.8 ft (10 m) IEC 61800-3 category C2 Integrated 164.04 ft (50 m) IEC 61800-3 category C3 With EMC plate option
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
ATV630D45N4Z — Mechanical & Cooling
ParameterValue
IP degree of protectionIP20IEC 61800-5-1 IP00 at bottom terminals)IEC 60529
Acoustic noise level63.5 dB
Cooling methodForced convection
Assembly / installation styleWith heat sink
ATV630D45N4Z — Environmental
ParameterValue
Operating ambient temperature5...122 °F (-15...50 °C) (without derating) 122...140 °F (50...60 °C) (with derating factor)
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV630D45N4Z — Approvals
ParameterValue
Certifications & markingCE
Standards complianceUL 508C IEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV630D45N4Z — Communication
ParameterValue
Communication protocolsModbus serial Ethernet Modbus TCP

Product details

The Schneider ATV630D45N4Z is a standard version Altivar Process drive rated for 45 kW normal duty at 380-480 V, with a continuous output current of 88 A at 4 kHz. That 88 A figure drives your cable sizing and upstream breaker selection — normal duty at 4 kHz gives you full torque down to a 4:1 speed range. The heavy duty rating (37 kW / 74.5 A) handles constant-torque loads like conveyors or extruders where you need more overload capacity. STO (safe torque off) SIL 3 is built in. No external safety relay for the stop circuit; just wire your safety contactor or safety PLC directly to the drive terminals. That saves a DIN-rail slot and a few wiring man-hours per panel. On the communication side, Modbus serial and Ethernet Modbus TCP are standard. Slot A accepts a Profibus DP V1, PROFINET, DeviceNet, CANopen, or Modbus TCP/EtherNet/IP module — whichever fieldbus your plant floor runs. The onboard Ethernet port handles most TCP-based applications without an option card. The integrated EMC filter meets IEC 61800-3 category C2 at 10 m and category C3 at 50 m (with the EMC plate). For most industrial environments you can skip the external filter bracket; just make sure you've got the proper gland plate and shielded motor cable to keep compliance.

Mounting and environmental notes

Cabinet mount with a heatsink and forced-convection fan. The cooling fan moves 240 m³/h at full speed — that means your enclosure ventilation grille needs free area roughly twice the fan sweep; check for obstructions near the intake. IP20 on the body (IP00 at the bottom terminals), so keep live parts behind a door. Mount vertically within 10 degrees of plumb; side-mounting or laying it flat kills the fan path and voids the thermal derating. Pollution degree 2, 95 % relative humidity (non-condensing). Altitude from 1000 m to 4800 m requires derating 1 % per 100 m above 1000 m. Vibration resistance: 1.5 mm peak-to-peak at 2–13 Hz, then 1 gn at 13–200 Hz (IEC 60068-2-6). Shock rating: 15 gn for 11 ms (IEC 60068-2-27). If your panel is mounted on a machine that sees repetitive impact (stamping press, crusher), add dampening feet or a sub-panel with isolation mounts.

Frequently asked questions

What is the CE marking status?

CE marking is listed on the spec. The drive also complies with UL 508C, IEC 61800-3, and several other standards including IEC 61508 for functional safety.

What variant is ATV630D45N4Z?

It is the Standard version. No option cards or special firmware pre-loaded.

What compliance documentation does this drive have?

The standards list includes UL 508C, IEC 61800-3 (environments 1 & 2, categories C2/C3), IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Marking: CE.

MPN
ATV630D45N4Z