Skip to main content
Schneider Electric ATV630U30N4US

Schneider ATV630U30N4US VSD, 3 kW, 380-480 V

MPN ATV630U30N4US
Active

Schneider Electric Altivar Process ATV600, ATV630U30N4US, variable speed drive, 3 kW normal duty, 380-480 V, integrated EMC filter.

$1,961.90 Ref. price · indicative, final on quote
Dispatch SLA24-48h Global Rush
Quality CheckOriginal Seal & Physical QC
IncotermsDAP / DDP Available
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & stockist· Listing updated Sep 2026

Specifications

ATV630U30N4US specifications
ParameterValue
Main product or component typeVariable speed drive
Frequency50...60 Hz - 5...5 %
IP ratingUL type 1 UL 508C
Temp storage max70 °C
Temp storage min-40 °C
Temp operating max70 °C
Temp operating min-40 °C
Storage temperature-40...158 °F (-40...70 °C)
Pollution degree2
Operating positionVertical +/- 10 degree

Product details

What this drive delivers

The integrated EMC filter covers cable runs up to 50 m for Category C2 (typical for first-industrial-environment) and 150 m for Category C3 (second-environment). That keeps you out of the external filter catalog for most installations. Safe Torque Off (STO) is built in at SIL 3 — no separate safety contactor needed for the usual press-to-stop or guard-interlock circuits. A single drive takes care of both motion control and the safety chain.

Standard onboard Ethernet Modbus TCP and serial Modbus. Drop a communication module into Slot A for Profibus, PROFINET, DeviceNet, or CANopen — pick the protocol your controller speaks, not the one that fits in a cramped terminal layout. Eight digital inputs are on the base board; DI7 and DI8 can be repurposed as 0-30 kHz pulse inputs for encoder-less speed feedback or flowmeter pulses. The 24 V DC sourcing is internal, so no extra power supply for the I/O rail. Regulation loop includes an adjustable PID — set it for pressure, level, or flow control without a separate controller. Tune the loop from the drive keypad or over the network.

Compliance and environmental fit

Listed under UL 508C and full IEC 61800 suite (safety, EMC, environment categories). TAA, BAA, and BABA compliant via the COTS clause — clears the federal procurement hurdle for US-government-funded projects without an additional compliance statement. Wall-mount, IP21 enclosure. Forced-convection cooling moves 38 m³/h of air, so check clearance above and below for free airflow. Operational from 0 to 4800 m with derating above 1000 m.

MPN
ATV630U30N4US