Skip to main content
Schneider Electric ATV650D75N4E — AC Drive (VFD) 480V

Schneider Electric ATV650D75N4E Altivar Process drive

MPNATV650D75N4E
Active

Schneider Electric Altivar Process ATV650D75N4E variable speed drive, 75 kW heavy duty / 100 hp normal duty, 380-480 V, 145 A nominal output, IP55, with integrated disconnect switch.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV650D75N4E — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV650
Product range / familyAltivar Process ATV600

Power & Output

ATV650D75N4E — Power & Output
ParameterValue
Motor power (kW)55 kW (heavy duty) 75 kW (normal duty)
Continuous output current106 A at 2.5 kHz for heavy duty 145 A at 2.5 kHz for normal duty

Input / Supply

ATV650D75N4E — Input / Supply
ParameterValue
Rated supply voltage range380...480 V
Input line current112.7 A at 480 V (normal duty) 98.9 A at 380 V (heavy duty) 86.9 A at 480 V (heavy duty) 131.3 A at 380 V (normal duty)

Control & Performance

ATV650D75N4E — Control & Performance
ParameterValue
Output frequency range0.1...500 Hz

Protection & EMC

ATV650D75N4E — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated with 150 m conforming to IEC 61800-3 category C3
EMC immunity testsRadiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2

Mechanical & Cooling

ATV650D75N4E — Mechanical & Cooling
ParameterValue
IP degree of protectionIP55 conforming to IEC 60529 IP55 conforming to IEC 61800-5-1
Acoustic noise level69.9 dB
Cooling methodForced convection

Environmental

ATV650D75N4E — Environmental
ParameterValue
Operating ambient temperature40...50 °C (with derating factor) -15...40 °C (without derating)
Operating altitude1000...4800 m with current derating 1 % per 100 m <= 1000 m without derating
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree3
Vibration resistance1 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6

Approvals

ATV650D75N4E — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-3 environment 1 category C2 EN/IEC 61800-3 environment 2 category C3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV650D75N4E — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

Active production — what that means for your BOM line

The ATV650D75N4E: This drive carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61508, and IEC 13849-1 — covering both EMC and functional safety for European installations.

Motor power and duty ratings — sizing the drive to the load

Rated 75 kW heavy duty and 100 hp normal duty, this drive handles asynchronous and synchronous motors. The heavy-duty rating is the one to use for constant-torque loads like conveyors or extruders; the normal-duty figure applies for variable-torque centrifugal pumps and fans. Continuous output current is 106 A at 2.5 kHz for heavy duty and 145 A at 2.5 kHz for normal duty. The nominal output current is 145.0 A. Line current varies by supply voltage and duty: 112.7 A at 480 V normal duty, 98.9 A at 380 V heavy duty.

Built-in disconnect switch and IP55 — panel integration notes

The variant with disconnect switch means the drive includes an integrated load-break switch on the input, simplifying panel wiring and meeting local isolation requirements without a separate external disconnect. IP55 protection (conforming to IEC 60529 and IEC 61800-5-1) allows wall-mount installation in washdown areas or dusty environments — no need for a separate enclosure in most process plant locations. Mounting position is vertical ±10 degrees. Ambient temperature range is -15 to 40 °C without derating, and up to 50 °C with derating. Above 1000 m altitude, derate current 1 % per 100 m up to 4800 m. Forced convection cooling; noise level is 69.9 dB.

Safety function and communication slots

Integrated STO (Safe Torque Off) rated SIL 3 per IEC 61508 — this is the safety function that removes torque from the motor without a separate contactor. It's the primary safety interface for hazard zones on a process line. Slot A accepts communication modules for PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (daisy chain RJ45, SUB-D 9, or screw terminals), Profibus DP V1, Ethernet Powerlink, and BACnet MS/TP. Slot A and slot B also accept digital/analog I/O extension and output relay extension modules. The drive ships with Ethernet, Modbus serial, and Modbus TCP as standard communication ports.

EMC filter and harmonic performance

Integrated EMC filter rated for 150 m cable length in category C3 environment (IEC 61800-3 environment 2, category C3). This means the drive is suitable for industrial power networks where the supply impedance is low — typical for factory floor installations. Maximum THDI is <48 % from 80-100 % load per IEC 61000-3-12.

Frequently asked questions

What compliance documentation does Schneider Electric provide for ATV650D75N4E?

The drive carries CE marking and complies with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61508 (functional safety, STO SIL 3), IEC 13849-1, IEC 61000-3-12 (harmonics), IEC 60721-3 (environmental), and IEC 60068-2-27/2-6 (shock/vibration). Pollution degree 3, overvoltage category III. Standard documentation includes the CE declaration of conformity and the product manual.

MPN