Skip to main content
Schneider Electric ATV6A0C11Q4 — AC Drive (VFD) 480V

Schneider ATV6A0C11Q4 Altivar Process ATV600, 110 kW Normal

MPNATV6A0C11Q4
Active

Schneider Altivar Process ATV600 modular drive, ATV6A0C11Q4, 110 kW / 90 kW heavy duty at 400 V, STO SIL 3, integrated EMC filter C3.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6A0C11Q4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6A0
Product range / familyAltivar Process ATV600

Power & Output

ATV6A0C11Q4 — Power & Output
ParameterValue
Motor power (kW)110.0 kW at 400 V normal duty 90.0 kW at 400 V heavy duty
Continuous output current211.0 A at 2.5 kHz normal duty 173.0 A at 2.5 kHz heavy duty
Max. transient current232.1 A during 60 s (normal duty) 259.5 A during 60 s (heavy duty)
Apparent power137 kVA at 400 V normal duty 116 kVA at 400 V heavy duty

Input / Supply

ATV6A0C11Q4 — Input / Supply
ParameterValue
Rated supply voltage range400 V - 15...10 %
Input line current198.0 A at 400 V (normal duty) 167.0 A at 400 V (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), <200 mA, protection type: overload and short-circuit protection

Control & Performance

ATV6A0C11Q4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor

Protection & EMC

ATV6A0C11Q4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated with 300 m conforming to IEC 61800-3 category C3
Protection functionsThermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA

Mechanical & Cooling

ATV6A0C11Q4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529
Acoustic noise level69 dB conforming to 86/188/EEC
Cooling methodForced convection

Environmental

ATV6A0C11Q4 — Environmental
ParameterValue
Operating ambient temperature-10...40 °C without derating 40...50 °C with derating factor
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV6A0C11Q4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV6A0C11Q4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

The ATV6A0C11Q4 is the modular, ready-to-install variant of the Altivar Process ATV600 family, rated 110 kW normal duty and 90 kW heavy duty at 400 V. The heavy-duty line current sits at 167 A, apparent power 116 kVA – figure for a 90 kW fan or pump drive that can handle short overloads. Normal duty pushes to 110 kW / 198 A / 137 kVA.

Control power and I/O

The drive needs a 24 V DC supply for the six digital inputs and the STO safety inputs, pulled from the control terminal block; internal protection is built in, rated under 200 mA. There is also a dedicated 10.5 V DC supply for a reference potentiometer (1–10 kΩ). Analog inputs AI1–AI3 are software-switchable between 0–10 V and 0/4–20 mA, 12-bit resolution, with a linearity error of ±0.15 % of maximum.

Communication and expandability

Slot A on the control unit accepts plug-in communication modules for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (with three connector options). Slot A/B also accept digital/analog I/O or relay extension modules. Built-in Modbus serial (2-wire RS-485) and Modbus TCP Ethernet are present on the base unit.

Frequently asked questions

What are the key motor power ratings for the ATV6A0C11Q4?

At 400 V, normal duty is 110 kW (198 A line current, 137 kVA apparent power), heavy duty is 90 kW (167 A line current, 116 kVA apparent power).

What control supply voltage does the ATV6A0C11Q4 require?

Digital inputs and STO need a 24 V DC supply (19–30 V tolerance), internal protection at <200 mA. A separate 10.5 V DC output is provided for a reference potentiometer.

What safety function does the ATV6A0C11Q4 support?

Safe Torque Off (STO) certified to SIL 3 per IEC 61508 and IEC 13849-1, wired directly to the STOA/STOB terminals on the control block.

MPN
ATV6A0C11Q4