ATV6A0C13S6 — Identification
ParameterValue
Product range / seriesAltivar Process ATV600
Device short name / model codeATV6A0
Product / component typeVariable speed drive
ATV6A0C13S6 — Electrical (input)
ParameterValue
Rated supply voltage600 V - 15...10 %
Network phases3 phases
Supply frequency50...60 Hz - 5...5 %
Line (input) current131.0 A 600 V normal duty) 112.0 A 600 V heavy duty)
Prospective line short-circuit current (Isc)50 kA
EMC filterIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Max. input current THD (THDi)<48 % full load IEC 61000-3-12
ATV6A0C13S6 — Output / Performance
ParameterValue
Apparent power136 kVA at 600 V normal duty 116 kVA at 600 V heavy duty
Continuous output current145.0 A at 2.5 kHz normal duty 125.0 A at 2.5 kHz heavy duty
Switching (PWM) frequency2...4.9 kHz adjustable with derating factor
ATV6A0C13S6 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP
Address range1...247 Modbus serial
Data format8 bits, configurable odd, even or no parity Modbus serial
ATV6A0C13S6 — Mechanical
ParameterValue
Mounting modeCabinet mount
Terminal / wiring connectionControl removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars
Product destination / compatibilitySynchronous motors Asynchronous motors
ATV6A0C13S6 — Environmental
ParameterValue
Degree of protection (IEC, IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration)
IP rating (with kit options)IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Storage temperature-40...158 °F (-40...70 °C)
Operating altitude (with derating)< 2000 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Pollution degree2 IEC 61800-5-1
Environmental resistance classesChemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
Shock resistance4 gn 11 ms IEC 60068-2-27
Acoustic noise level69 dB 86/188/EEC
ATV6A0C13S6 — Approvals & Compliance
ParameterValue
StandardsIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1
Agency markings / approvalsCE

Product details

At a glance

The Schneider ATV6A0C13S6 is a modular Altivar Process ATV600 drive rated for 150 hp at 600 V normal duty with a line current of 131 A (112 A heavy duty). It handles both asynchronous and synchronous motors and comes with an integrated EMC filter meeting IEC 61800-3 category C3 for cable runs up to 300 m — no external filter needed for most CE-marked industrial installations. Safety is built in: Safe Torque Off (STO) rated SIL 3 eliminates the need for a separate safety relay when stopping torque is the risk. The protection suite covers motor and drive thermal, phase loss, overcurrent, overvoltage, undervoltage, and DC bus faults — most of what a VFD fault log will throw at you.

Safety and compliance

The drive carries CE marking and complies with a broad set of IEC and UL standards: IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonic limits), IEC 60721-3 (environmental), IEC 61508 / IEC 13849-1 (functional safety), and UL 61800-5-1. Pollution degree 2 per IEC 61800-5-1, designed for typical industrial control panels. Total harmonic current distortion (THDi) is guaranteed below 48 % at full load per IEC 61000-3-12, which keeps line harmonics within limits without an external line reactor in many installations.

On the network

Slot A accepts a choice of communication modules: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (RJ45, SUB-D 9, or screw terminals). The base unit includes a Modbus serial port (2-wire RS-485, RTU, up to 38.4 kbit/s) and a Modbus TCP Ethernet port (10/100 Mbit/s, half/full duplex, auto-negotiation). For I/O expansion, Slot A or B takes a digital/analog extension or a relay output module. The modular version means the control unit and power module can be separated — a mechanical mounting kit and power connection set are included in the box. That simplifies panel layout when the operator interface needs to sit on a door and the heat-generating part stays in the cabinet.

Sourcing

The ATV600 series is an active, in-production drive. Its modular version supports fieldbus options like Profibus DP V1, PROFINET, and DeviceNet.

Frequently asked questions

What are the key ratings of the ATV6A0C13S6?

It is rated 150 hp at 600 V normal duty (125 hp heavy duty), with a line current of 131 A normal duty (112 A heavy duty). Integrated EMC filter C3 for 300 m cable.