Specifications

ATV6A0C16T4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6A0
Product range / familyAltivar Process ATV600
ATV6A0C16T4 — Power & Output
ParameterValue
Motor power (kW)160.0 kW at 480 V normal duty 132.0 kW at 480 V heavy duty
Continuous output current302.0 A at 2.5 kHz normal duty 250.0 A at 2.5 kHz heavy duty
Max. transient current332.2 A 60 s normal duty) 375 A 60 s heavy duty)
Apparent power223 kVA at 480 V normal duty 181 kVA at 480 V heavy duty
ATV6A0C16T4 — Input / Supply
ParameterValue
Rated supply voltage range480 V - 15...10 %
Input line current268.0 A 480 V normal duty) 218.0 A 480 V heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), <200 mA overload and short-circuit protection
ATV6A0C16T4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor
ATV6A0C16T4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA
ATV6A0C16T4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Acoustic noise level69 dB 86/188/EEC
Cooling methodForced convection
ATV6A0C16T4 — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV6A0C16T4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV6A0C16T4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

This Altivar Process ATV600 modular drive – the ATV6A0C16T4 – is a 160 kW unit meant for 480 V three-phase. Out here in the grease, you'll appreciate the forced convection cooling that keeps it going in a dirty cabinet, and the integrated EMC filter (C3) saves you an external box. The supply for the digital inputs and STO is separate at 24 V DC (21...27 V), so watch your wiring. Cabinet mount only. The analog inputs and outputs hold accuracy within 0.6% over 60°C, so the readings stay honest even when the panel heats up. You can config those analog inputs for voltage or current. The safety torque off (STO) is SIL 3, which means you can work on the motor side without killing the whole line – just the drive.

Integration details

Analog inputs are software-configurable 0-10 V or 0/4-20 mA, 12-bit resolution, linearity error ±0.15%. The supply for the reference pot gives 10.5 V DC at 1-10 kOhm.

Frequently asked questions

What is the ATV6A0C16T4's listed supply for digital inputs and STO?

The digital inputs and STO require an external 24 V DC supply in the range 21...27 V, with overload and short-circuit protection at <200 mA. There is also a separate 10.5 V DC supply for a reference potentiometer (1 to 10 kOhm).

What markings and certifications does the ATV6A0C16T4 carry?

It carries CE marking and conforms to IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1.

What is the normal duty horsepower rating?

At 480 V normal duty, it is rated 250 hp, 160 kW.

MPN
ATV6A0C16T4