Skip to main content
Schneider Electric ATV6A0C25Q4 — AC Drive (VFD) 480V

Schneider ATV6A0C25Q4 Altivar Process 250 kW Drive

MPNATV6A0C25Q4
Active

Schneider Electric, Altivar Process ATV600 series, modular variable speed drive, ATV6A0C25Q4, 250 kW at 400 V (normal duty), 432 A line current, integrated EMC filter, STO SIL 3.

StockContact for availability
Lead time3-5 Days wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6A0C25Q4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6A0
Product range / familyAltivar Process ATV600

Power & Output

ATV6A0C25Q4 — Power & Output
ParameterValue
Motor power (kW)250.0 kW at 400 V normal duty 200.0 kW at 400 V heavy duty
Continuous output current477.0 A at 2.5 kHz normal duty 370.0 A at 2.5 kHz heavy duty
Max. transient current524.7 A during 60 s (normal duty) 555 A during 60 s (heavy duty)
Apparent power299 kVA at 400 V normal duty 245 kVA at 400 V heavy duty

Input / Supply

ATV6A0C25Q4 — Input / Supply
ParameterValue
Rated supply voltage range400 V - 15...10 %
Input line current432.0 A at 400 V (normal duty) 353.0 A at 400 V (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), <200 mA, protection type: overload and short-circuit protection

Control & Performance

ATV6A0C25Q4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor

Protection & EMC

ATV6A0C25Q4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated with 300 m conforming to IEC 61800-3 category C3
Protection functionsThermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA

Mechanical & Cooling

ATV6A0C25Q4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529
Acoustic noise level70 dB conforming to 86/188/EEC
Cooling methodForced convection

Environmental

ATV6A0C25Q4 — Environmental
ParameterValue
Operating ambient temperature-10...40 °C without derating 40...50 °C with derating factor
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV6A0C25Q4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV6A0C25Q4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

Schneider Electric ATV6A0C25Q4 is a modular Altivar Process ATV600 variable speed drive rated for 250 kW motor power at 400 V in normal duty, or 200 kW in heavy duty. Line current pulls 432 A at normal duty, 353 A at heavy duty, which sets the supply conductor and upstream protection size. This is the modular variant, meaning the drive ships as a kit with separate control unit, power modules, and mounting hardware — field assembly required. Not a compact all-in-one; plan for panel integration time.

Supply and I/O

Digital inputs need 24 V DC external supply (19...30 V). Internal 24 V supply for digital inputs and STO is 21...27 V, <200 mA, with overload and short-circuit protection. Analog inputs accept 0...10 V DC or 0...20 mA/4...20 mA, 12-bit. Six discrete inputs at 24 V DC, two configurable as pulse inputs 0...30 kHz.

Safety and Compliance

Integrated EMC filter meets category C3 with 300 m cable length. Drive complies with IEC 61800-3, IEC 61000-3-12, IEC 60721-3. Marking CE.

Communication Slots

Slot A accepts a communication module for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (multiple connector variants). Slot A/B also supports digital/analog I/O extension or output relay extension. Embedded Modbus serial (RS-485) and Modbus TCP (Ethernet) standard.

Frequently asked questions

What are the key electrical ratings for the ATV6A0C25Q4?

Rated 250 kW motor power at 400 V in normal duty (432 A line current) and 200 kW at 400 V in heavy duty (353 A line current).

What is the supply requirement for the digital inputs and STO?

External 24 V DC (19...30 V) supply for digital inputs. Internal supply for STO and digital inputs is 24 V DC (21...27 V) with overload and short-circuit protection, <200 mA.

What compliance certifications does this drive carry?

Marked CE and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1.

MPN
ATV6A0C25Q4