Skip to main content
Schneider Electric ATV6A0C40T4 — AC Drive (VFD) 480V

Schneider Electric ATV6A0C40T4 Altivar Process 600, 600 hp

MPNATV6A0C40T4
Active

Schneider Electric Altivar Process ATV600, ATV6A0C40T4, modular drive, 600 hp normal duty, 500 hp heavy duty at 480 V.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV6A0C40T4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6A0
Product range / familyAltivar Process ATV600
ATV6A0C40T4 — Power & Output
ParameterValue
Motor power (kW)400.0 kW at 480 V normal duty 315.0 kW at 480 V heavy duty
Continuous output current730.0 A at 2.5 kHz normal duty 590.0 A at 2.5 kHz heavy duty
Max. transient current803 A 60 s normal duty) 885 A 60 s heavy duty)
Apparent power527 kVA at 480 V normal duty 446 kVA at 480 V heavy duty
ATV6A0C40T4 — Input / Supply
ParameterValue
Rated supply voltage range480 V - 15...10 %
Input line current634.0 A 480 V normal duty) 536.0 A 480 V heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), <200 mA overload and short-circuit protection
ATV6A0C40T4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor
ATV6A0C40T4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA
ATV6A0C40T4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Acoustic noise level71 dB 86/188/EEC
Cooling methodForced convection
ATV6A0C40T4 — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV6A0C40T4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV6A0C40T4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

The Schneider Electric ATV6A0C40T4 is an Altivar Process ATV600 modular drive rated for 600 hp normal duty and 500 hp heavy duty at 480 V, with corresponding apparent power of 527 kVA and 446 kVA respectively. It carries integrated EMC filtering to IEC 61800-3 category C3 for 300 m cable runs, reducing the need for external filters in most industrial lineups. Safe torque off (STO) is included at SIL 3 per IEC 61508, covering both drive and motor phases for machine safety integration.

Compliance documentation covers IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12 (harmonics), IEC 60721-3 (environmental), IEC 61508, and IEC 13849-1. CE marked.

Integration Notes

Cabinet-mount forced-convection cooled drive. Slot A accepts communication modules for Profibus DP, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen, plus digital/analog I/O or relay extensions in slots A/B. Digital inputs are 24 V DC (19–30 V range), with separate internal supply for STO and reference potentiometer. Modbus serial via 2-wire RS485 at 4.8–38.4 kbit/s; Ethernet at 10/100 Mbit/s.

Frequently asked questions

What compliance documentation does this drive carry?

It meets IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. CE marked.

What are the supply voltage requirements?

Digital inputs require 24 V DC (19–30 V). Separate internal supplies provide 10.5 V DC for a reference potentiometer and 24 V DC (21–27 V) for digital inputs and STO, with overload and short-circuit protection under 200 mA.

MPN
ATV6A0C40T4