Skip to main content
Schneider Electric ATV6A0C40T6 — AC Drive (VFD) 600V

Schneider ATV6A0C40T6 Altivar Process 600 Drive, 450 hp

MPNATV6A0C40T6
Active

Schneider Electric Altivar Process ATV600 series, ATV6A0C40T6, modular version variable speed drive, 450 hp at 600 V normal duty, 379 A line current, cabinet mount.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV6A0C40T6 — Identification
ParameterValue
Product range / seriesAltivar Process ATV600
Device short name / model codeATV6A0
Product / component typeVariable speed drive
ATV6A0C40T6 — Electrical (input)
ParameterValue
Rated supply voltage600 V - 15...10 %
Network phases3 phases
Supply frequency50...60 Hz - 5...5 %
Line (input) current379.0 A 600 V normal duty) 298.0 A 600 V heavy duty)
Prospective line short-circuit current (Isc)50 kA
EMC filterIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Max. input current THD (THDi)<48 % full load IEC 61000-3-12
ATV6A0C40T6 — Output / Performance
ParameterValue
Apparent power394 kVA at 600 V normal duty 310 kVA at 600 V heavy duty
Continuous output current425.0 A at 2.5 kHz normal duty 340.0 A at 2.5 kHz heavy duty
Switching (PWM) frequency2...4.9 kHz adjustable with derating factor
ATV6A0C40T6 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP
Address range1...247 Modbus serial
Data format8 bits, configurable odd, even or no parity Modbus serial
ATV6A0C40T6 — Mechanical
ParameterValue
Mounting modeCabinet mount
Terminal / wiring connectionControl removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars
Product destination / compatibilitySynchronous motors Asynchronous motors
ATV6A0C40T6 — Environmental
ParameterValue
Degree of protection (IEC, IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP rating (with kit options)IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Storage temperature-40...158 °F (-40...70 °C)
Operating altitude (with derating)< 2000 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Pollution degree2 IEC 61800-5-1
Environmental resistance classesChemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
Shock resistance4 gn 11 ms IEC 60068-2-27
Acoustic noise level70 dB 86/188/EEC
ATV6A0C40T6 — Approvals & Compliance
ParameterValue
StandardsIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1
Agency markings / approvalsCE

Product details

The Schneider ATV6A0C40T6 is a current-production Altivar Process ATV600 drive in the modular version, rated 450 hp at 600 V normal duty and 350 hp at 600 V heavy duty. It handles synchronous and asynchronous motors, output voltage up to line supply, and includes integrated STO SIL3 safety function. Line current is 379 A normal duty (298 A heavy duty) with a prospective short-circuit rating of 50 kA.

Ratings that matter for selection

The dual-duty rating let you size for either normal or heavy-duty motor loads — 450 hp vs 350 hp on 600 V — giving a derating path for constant-torque applications. Switching frequency is adjustable from 2 to 4.9 kHz with derating; the integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs. Protection covers motor and drive thermal, phase break, overcurrent, earth fault, DC bus overvoltage, line supply undervoltage/overvoltage, phase loss, and overspeed.

As a modular version, the kit includes the power module, control unit, mounting hardware, fuses, and front cover — a complete drive package that simplifies procurement. All compliance documentation (CE, UL, IEC 61800, IEC 61508, IEC 13849-1) is on file. This drive can be specified with confidence into any machine design requiring SIL3 STO. For exact BOM fit, submit an RFQ — we confirm the line current, motor power, and options (slot A communication cards, I/O extensions) against your application.

Cabinet-mount design with forced convection cooling. Accepts UL type 1 or type 12 enclosures when integrated into a cabinet. Communication options cover Modbus serial (RS-485), Modbus TCP, PROFIBUS DP V1, PROFINET, DeviceNet, CANopen, and Ethernet/IP through slot A cards. Vibration resistance is 1.5 mm peak-to-peak (2–13 Hz) and 0.5 gn (13–200 Hz) per IEC 60068-2-6; shock resistance is 4 gn for 11 ms per IEC 60068-2-27. Operating altitude up to 2000 m with derating above 1000 m; relative humidity 5–95% non-condensing; pollution degree 2.

Frequently asked questions

What are the key compliance certifications for ATV6A0C40T6?

It carries CE marking and conforms to IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 61800-5-1.

What is the listed variant of this drive?

The ATV6A0C40T6 is the modular version of the Altivar Process ATV600 drive, supplied as a kit with the power module, control unit, and mounting hardware.

What is the CE marking status?

The drive carries CE marking as listed in the specifications.

MPN