Skip to main content
Schneider Electric ATV6A0C50Q4 — AC Drive (VFD) 480V

Schneider ATV6A0C50Q4 Altivar Process 600, 500 kW Drive

MPNATV6A0C50Q4
Active

Schneider Altivar Process ATV600 modular drive, 500 kW normal duty / 400 kW heavy duty at 400 V, integrated EMC filter C3, STO SIL 3, Modbus TCP.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ATV6A0C50Q4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6A0
Product range / familyAltivar Process ATV600
ATV6A0C50Q4 — Power & Output
ParameterValue
Motor power (kW)500.0 kW at 400 V normal duty 400.0 kW at 400 V heavy duty
Continuous output current900.0 A at 2.5 kHz normal duty 730.0 A at 2.5 kHz heavy duty
Max. transient current990 A during 60 s (normal duty) 1095 A during 60 s (heavy duty)
Apparent power586 kVA at 400 V normal duty 472 kVA at 400 V heavy duty
ATV6A0C50Q4 — Input / Supply
ParameterValue
Rated supply voltage range400 V - 15...10 %
Input line current846.0 A at 400 V (normal duty) 681.0 A at 400 V (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), <200 mA, protection type: overload and short-circuit protection
ATV6A0C50Q4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor
ATV6A0C50Q4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated with 300 m conforming to IEC 61800-3 category C3
Protection functionsThermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA
ATV6A0C50Q4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529
Acoustic noise level71 dB conforming to 86/188/EEC
Cooling methodForced convection
ATV6A0C50Q4 — Environmental
ParameterValue
Operating ambient temperature-10...40 °C without derating 40...50 °C with derating factor
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV6A0C50Q4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV6A0C50Q4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

Drive rating and fit for your motor load

The Schneider ATV6A0C50Q4 is an Altivar Process ATV600 modular drive rated 500 kW at 400 V in normal duty (ND) and 400 kW in heavy duty (HD). The corresponding line current is 846 A ND and 681 A HD at 400 V, so your motor and cable should be sized for those currents. The drive outputs voltage up to the supply level and covers a supply frequency of 50...60 Hz ±5%. It ships as a modular kit: one control unit, mounting hardware, power connections, fuses, three 160 kW power modules, and two front covers. The cabinet-mount design uses forced convection cooling and is rated for pollution degree 2 per IEC 61800-5-1.

Control interface and I/O specifics

Analog inputs (AI1, AI2, AI3) are software-configurable for voltage (0-10 V DC, 30 kOhm) or current (0-20 mA / 4-20 mA, 250 Ohm), 12-bit resolution, with a linearity error of ±0.15% and accuracy ±0.6% over a 60°C drift. Analog outputs (AO1, AO2) are ±1% accurate. Relay outputs: one configurable fault relay (NO/NC) and two sequence relays (NO), all rated for 100,000 cycles electrical.

Communication and options

The drive comes with embedded Modbus serial (2-wire RS-485, RTU format) and Modbus TCP over Ethernet (10/100 Mbit/s, half/full duplex, auto-negotiation). Slot A accepts option cards for Profibus DP V1, PROFINET, DeviceNet, CANopen, or Modbus TCP/EtherNet/IP. Slots A/B can also hold digital/analog I/O extension or output relay extension modules. This makes fieldbus slice integration straightforward for most automation architectures.

Safety, EMC, and standards compliance

The integrated STO function achieves SIL 3 per IEC 61508 / IEC 13849-1, covering motor and drive thermal protection, safe torque off, overcurrent, earth fault, short-circuit, DC bus overvoltage, line supply phase loss, and overspeed. The EMC filter is integrated and supports 300 m of shielded motor cable while meeting IEC 61800-3 category C3 (second environment, industrial). Harmonic current THDI is under 48% full load per IEC 61000-3-12.

Frequently asked questions

What is the motor power rating of this drive?

500 kW at 400 V in normal duty and 400 kW at 400 V in heavy duty.

What safety functions does it support?

STO (safe torque off) to SIL 3, plus motor and drive thermal protection, overcurrent, earth fault, short-circuit, and line supply monitoring.

Does this drive have an integrated EMC filter?

Yes, it includes an integrated EMC filter rated for 300 m of shielded motor cable, meeting IEC 61800-3 category C3.

MPN
ATV6A0C50Q4