Schneider ATV6A0C56Q4 Altivar Process ATV600 Drive, 560 kW N

MPNATV6A0C56Q4
Active

Schneider Electric Altivar Process ATV600 modular drive, ATV6A0C56Q4, 560 kW at 400 V normal duty, 450 kW heavy duty, integrated EMC filter, STO SIL 3.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6A0C56Q4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6A0
Product range / familyAltivar Process ATV600

Power & Output

ATV6A0C56Q4 — Power & Output
ParameterValue
Motor power (kW)560.0 kW at 400 V normal duty 450.0 kW at 400 V heavy duty
Continuous output current1020.0 A at 2.5 kHz normal duty 830.0 A at 2.5 kHz heavy duty
Max. transient current1122 A during 60 s (normal duty) 1245 A during 60 s (heavy duty)
Apparent power657 kVA at 400 V normal duty 531 kVA at 400 V heavy duty

Input / Supply

ATV6A0C56Q4 — Input / Supply
ParameterValue
Rated supply voltage range400 V - 15...10 %
Input line current948.0 A at 400 V (normal duty) 767.0 A at 400 V (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), <200 mA, protection type: overload and short-circuit protection

Control & Performance

ATV6A0C56Q4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor

Protection & EMC

ATV6A0C56Q4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated with 300 m conforming to IEC 61800-3 category C3
Protection functionsThermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA

Mechanical & Cooling

ATV6A0C56Q4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529
Acoustic noise level73 dB conforming to 86/188/EEC
Cooling methodForced convection

Environmental

ATV6A0C56Q4 — Environmental
ParameterValue
Operating ambient temperature-10...40 °C without derating 40...50 °C with derating factor
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV6A0C56Q4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV6A0C56Q4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

The Schneider ATV6A0C56Q4 is a modular Altivar Process ATV600 drive rated for 560 kW at 400 V normal duty and 450 kW at 400 V heavy duty, with corresponding line currents of 948 A and 767 A. Apparent power runs 657 kVA (ND) and 531 kVA (HD). The integrated EMC filter supports up to 300 m of motor cable per IEC 61800-3 category C3, which covers most industrial installations without an external filter. Supply architecture is split: the digital inputs and STO circuit need a 24 V DC supply (21...27 V for STO, 19...30 V for general digital inputs), drawn from an external source at under 200 mA with built-in overload and short-circuit protection. A separate 10.5 V DC reference is available for a 1 to 10 kOhm potentiometer. This avoids pulling control power from the main DC bus, which simplifies isolation in a safety loop. The drive carries STO (safe torque off) rated SIL 3, meeting IEC 61508 and IEC 13849-1. It also complies with IEC 61800-5-1, IEC 61000-3-12, and IEC 60721-3. CE marked.

Fieldbus and I/O slice

Slot A accepts communication modules for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen (daisy chain RJ45, SUB-D 9, or screw terminals). Slot A and slot B can also take digital/analog I/O extension or output relay modules. The base unit includes embedded Modbus TCP slave (10/100 Mbit/s) and a 2-wire RS 485 Modbus serial port running RTU at 4.8 to 38.4 kbit/s. Discrete inputs DI1–DI6 are 24 V DC, with DI5 and DI6 configurable as pulse inputs up to 30 kHz. Analog inputs AI1–AI3 are software-configurable for 0–10 V DC or 0/4–20 mA, 12-bit resolution. Analog outputs AO1–AO2 are also configurable. Sampling times: 2 ms for fast DI, 5 ms for standard DI and AI, 10 ms for AO. Three configurable relay outputs (R1 fault NO/NC, R2 and R3 sequence NO) rated for 100,000 cycles, with 5 ms refresh.

Frequently asked questions

What are the key motor power ratings for the ATV6A0C56Q4?

The drive is rated for 560 kW at 400 V in normal duty and 450 kW at 400 V in heavy duty, with corresponding line currents of 948 A and 767 A.

What safety function does the ATV6A0C56Q4 support?

It supports Safe Torque Off (STO) rated SIL 3, compliant with IEC 61508 and IEC 13849-1.

What fieldbus options are available for this drive?

Slot A accepts modules for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen. The drive also has embedded Modbus TCP and RS 485 Modbus serial.

What is the integrated EMC filter rating?

The integrated EMC filter supports up to 300 m of motor cable per IEC 61800-3 category C3.

MPN
ATV6A0C56Q4