Skip to main content
Schneider Electric ATV6A0C56T4 — AC Drive (VFD) 480V

Altivar ATV6A0C56T4 560 kW Drive, 842 A, STO SIL 3

MPNATV6A0C56T4
Active

Schneider Electric Altivar Process ATV600, modular drive ATV6A0C56T4: 560 kW at 480 V normal duty, 842 A line current, STO SIL 3, integrated EMC filter category C3, cabinet mount.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6A0C56T4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6A0
Product range / familyAltivar Process ATV600

Power & Output

ATV6A0C56T4 — Power & Output
ParameterValue
Motor power (kW)560.0 kW at 480 V normal duty 450.0 kW at 480 V heavy duty
Continuous output current1020.0 A at 2.5 kHz normal duty 830.0 A at 2.5 kHz heavy duty
Max. transient current1122 A 60 s normal duty) 1245 A 60 s heavy duty)
Apparent power700 kVA at 480 V normal duty 574 kVA at 480 V heavy duty

Input / Supply

ATV6A0C56T4 — Input / Supply
ParameterValue
Rated supply voltage range480 V - 15...10 %
Input line current842.0 A 480 V normal duty) 690.0 A 480 V heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), <200 mA overload and short-circuit protection

Control & Performance

ATV6A0C56T4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor

Protection & EMC

ATV6A0C56T4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA

Mechanical & Cooling

ATV6A0C56T4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Acoustic noise level73 dB 86/188/EEC
Cooling methodForced convection

Environmental

ATV6A0C56T4 — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV6A0C56T4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV6A0C56T4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

The ATV6A0C56T4 is a modular Altivar Process ATV600 drive rated for 560 kW (800 hp) at 480 V normal duty and 450 kW (650 hp) heavy duty, pulling 842 A and 690 A line current respectively. It includes integrated STO SIL 3 safety function and an EMC filter rated for 300 m of motor cable under IEC 61800-3 category C3. For continuous overload applications, the heavy-duty curve is the one that governs pump sizing — that 650 hp at 480 V is the number that matters. Active in production, it ships as a complete kit with control unit, power modules, mounting hardware, and fuses. The modular version accepts field-fit communication cards (Profibus DP, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen) and I/O relay extension via slot A and slot B.

Controls integrators should note the supply architecture: external 24 V DC (19…30 V) for the six digital inputs, while an internal 24 V DC supply (21…27 V, <200 mA protected) powers the STO channels and the reference potentiometer bus (10.5 V DC, 1…10 kΩ).

Cabinet-mounted, forced-convection cooled. The integrated EMC filter meets C3 for a 300 m motor cable — adequate for most water/wastewater lift stations without an external filter. Pollution degree 2, shock 7 gn, altitude derating above 1000 m at 1% per 100 m. Onboard diagnostics: three dual-colour LEDs for embedded communication, four for the option card, plus relay outputs for fault and sequence (NO/NC, 100000 cycles).

Frequently asked questions

What compliance standards does it meet?

It complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Marked CE.

What are the normal-duty and heavy-duty motor ratings?

At 480 V, normal duty: 560 kW (800 hp), 842 A line current, 700 kVA. Heavy duty: 450 kW (650 hp), 690 A line current, 574 kVA.

MPN