Skip to main content
Schneider Electric ATV6A0C63Q4 — AC Drive (VFD) 480V

Schneider ATV6A0C63Q4 Altivar Process Drive, 630 kW

MPNATV6A0C63Q4
Active

Schneider Altivar Process ATV600 series, ATV6A0C63Q4, modular drive, 630 kW normal duty at 400 V, 733 kVA, line current 1058 A, integrated EMC filter C3, Modbus TCP.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

ATV6A0C63Q4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6A0
Product range / familyAltivar Process ATV600
ATV6A0C63Q4 — Power & Output
ParameterValue
Motor power (kW)630.0 kW at 400 V normal duty 500.0 kW at 400 V heavy duty
Continuous output current1140.0 A at 2.5 kHz normal duty 900.0 A at 2.5 kHz heavy duty
Max. transient current1254 A during 60 s (normal duty) 1350 A during 60 s (heavy duty)
Apparent power733 kVA at 400 V normal duty 588 kVA at 400 V heavy duty
ATV6A0C63Q4 — Input / Supply
ParameterValue
Rated supply voltage range400 V - 15...10 %
Input line current1058.0 A at 400 V (normal duty) 849.0 A at 400 V (heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs: 24 V DC (19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO: 24 V DC (21...27 V), <200 mA, protection type: overload and short-circuit protection
ATV6A0C63Q4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor
ATV6A0C63Q4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated with 300 m conforming to IEC 61800-3 category C3
Protection functionsThermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA
ATV6A0C63Q4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529
Acoustic noise level73 dB conforming to 86/188/EEC
Cooling methodForced convection
ATV6A0C63Q4 — Environmental
ParameterValue
Operating ambient temperature-10...40 °C without derating 40...50 °C with derating factor
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV6A0C63Q4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV6A0C63Q4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

Hardware for a 630 kW machine. The ATV6A0C63Q4 ships as a kit: one control unit, four 160 kW power modules, mounting hardware, and a set of fuses. You're looking at a cabinet-mount drive rated 733 kVA normal duty at 400 V, drawing 1058 A line current. The integrated EMC filter meets IEC 61800-3 Category C3 with up to 300 m of motor cable—saves you an external box. On the control side, you get six programmable digital inputs (two can be configured as pulse inputs up to 30 kHz), three analog inputs, two analog outputs, and three relay outputs. The embedded Modbus TCP port runs at 10/100 Mbit/s, and slot A accepts a Profibus, PROFINET, DeviceNet, CANopen, or Ethernet/IP module.

Cabinet mount, forced-air cooling. Pollution degree 2 environment. Operate between 1000 m and 4800 m with a 1 % derating per 100 m above 1000 m. Relative humidity 5…95 % non-condensing. Shock resistance 7 gn for 11 ms. The supply frequency must be 50/60 Hz ±5 %. All digital inputs take 24 V DC nominal (19…30 V), and the internal supply for STO and digital inputs is rated <200 mA with overload protection. For potentiometer wipers, there's a 10.5 V DC reference supply. Watch the line current: 1058 A at 400 V ND is not a small feeder—make sure your upstream protection and conductor sizing match.

Frequently asked questions

What compliance documentation does the ATV6A0C63Q4 carry?

It is CE marked and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. It also includes a built-in STO safety function rated SIL 3.

What are the supply voltage requirements for the digital inputs and STO?

Digital inputs accept 24 V DC (19...30 V). The internal supply for digital inputs and STO is 24 V DC (21...27 V) rated at less than 200 mA with overload and short-circuit protection.

What is the EMC filter rating on this drive?

The integrated EMC filter conforms to IEC 61800-3 Category C3 and supports up to 300 m of motor cable, eliminating the need for an external filter in most industrial installations.

MPN