Schneider Electric ATV6A0C80T4 — AC Drive (VFD) 480V

Schneider ATV6A0C80T4 Altivar Process ATV600, 800 kW/1100 hp

MPNATV6A0C80T4
Active

Schneider Electric Altivar Process ATV600, modular variable speed drive, ATV6A0C80T4, 800 kW / 1100 hp at 480 V normal duty, 630 kW / 900 hp heavy duty, STO SIL 3, integrated EMC filter.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6A0C80T4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6A0
Product range / familyAltivar Process ATV600

Power & Output

ATV6A0C80T4 — Power & Output
ParameterValue
Motor power (kW)800.0 kW at 480 V normal duty 630.0 kW at 480 V heavy duty
Continuous output current1420.0 A at 2.5 kHz normal duty 1140.0 A at 2.5 kHz heavy duty
Max. transient current1562 A 60 s normal duty) 1710 A 60 s heavy duty)
Apparent power953 kVA at 480 V normal duty 783 kVA at 480 V heavy duty

Input / Supply

ATV6A0C80T4 — Input / Supply
ParameterValue
Rated supply voltage range480 V - 15...10 %
Input line current1146.0 A 480 V normal duty) 942.0 A 480 V heavy duty)
Network number of phases3 phases
Internal/auxiliary suppliesExternal supply for digital inputs 24 V DC 19...30 V), Internal supply for reference potentiometer (1 to 10 kOhm) 10.5 V DC +/- 5 %, Internal supply for digital inputs and STO 24 V DC 21...27 V), <200 mA overload and short-circuit protection

Control & Performance

ATV6A0C80T4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor

Protection & EMC

ATV6A0C80T4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA

Mechanical & Cooling

ATV6A0C80T4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Acoustic noise level74 dB 86/188/EEC
Cooling methodForced convection

Environmental

ATV6A0C80T4 — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Operating altitude1000...4800 m with current derating 1 % per 100 m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV6A0C80T4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV6A0C80T4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

The ATV6A0C80T4 is a modular Altivar Process ATV600 drive rated for 800 kW (1100 hp) at 480 V normal duty and 630 kW (900 hp) at 480 V heavy duty. Line current draws 1146 A normal duty, 942 A heavy duty. Apparent power is 953 kVA normal, 783 kVA heavy. The drive includes integrated EMC filter rated for 300 m motor cable (IEC 61800-3 category C3). Supply architecture is split: digital inputs take 24 V DC (19...30 V), an internal 10.5 V DC ±5% supply powers a 1 to 10 kΩ reference potentiometer, and the STO circuit runs on a separate 24 V DC (21...27 V) supply with <200 mA overload and short-circuit protection. The three supplies are isolated — the STO rail is not shared with the control logic.

Safety and compliance

The drive carries CE marking and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, and IEC 61000-3-12. Total harmonic current distortion (THDI) is below 48% at full load per IEC 61000-3-12. Lifecycle stage is current production.

Integration and options

The drive accepts communication option cards in Slot A: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (daisy chain RJ45, SUB-D 9, or screw terminals). Slot A and Slot B also accept digital/analog I/O extension modules and output relay extension modules. Embedded Modbus serial runs at 4.8 to 38.4 kbit/s (RTU, 2-wire RS-485); Ethernet/Modbus TCP runs at 10/100 Mbit/s with half/full duplex and autonegotiation. Analog inputs AI1, AI2, AI3 are software-configurable for voltage (0...10 V DC, 30 kΩ, 12 bits) or current (0...20 mA / 4...20 mA, 250 Ω, 12 bits). Linearity error is ±0.15% of maximum value; accuracy drift across a 60 °C temperature variation is ±0.6% for inputs, ±1% for outputs. Discrete inputs DI1...DI6 are 24 V DC programmable; DI5 and DI6 accept pulse inputs up to 30 kHz.

Cabinet mount, forced convection cooling. Pollution degree 2 per IEC 61800-5-1. Operating altitude up to 1000 m without derating; above that, derate 1% per 100 m to 4800 m. Relative humidity 5...95% without condensation. Shock resistance 7 gn for 11 ms per IEC 60068-2-27. Noise level 74 dB per 86/188/EEC.

Frequently asked questions

What is the motor power rating of the ATV6A0C80T4?

800 kW (1100 hp) at 480 V normal duty, 630 kW (900 hp) at 480 V heavy duty.

What communication option cards fit the ATV6A0C80T4?

Slot A accepts Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen modules. Slot A and B also accept digital/analog I/O extension and output relay extension modules.

What is the EMC filter rating on the ATV6A0C80T4?

Integrated EMC filter rated for 300 m motor cable, meeting IEC 61800-3 category C3.

MPN
ATV6A0C80T4