ATV6A0C80T6 — Identification
ParameterValue
Product range / seriesAltivar Process ATV600
Device short name / model codeATV6A0
Product / component typeVariable speed drive
ATV6A0C80T6 — Electrical (input)
ParameterValue
Rated supply voltage600 V - 15...10 %
Network phases3 phases
Supply frequency50...60 Hz - 5...5 %
Line (input) current670.0 A 600 V normal duty) 547.0 A 600 V heavy duty)
Prospective line short-circuit current (Isc)50 kA
EMC filterIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Max. input current THD (THDi)<48 % full load IEC 61000-3-12
ATV6A0C80T6 — Output / Performance
ParameterValue
Apparent power696 kVA at 600 V normal duty 568 kVA at 600 V heavy duty
Continuous output current830.0 A at 2.5 kHz normal duty 650.0 A at 2.5 kHz heavy duty
Switching (PWM) frequency2...4.9 kHz adjustable with derating factor
ATV6A0C80T6 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP
Address range1...247 Modbus serial
Data format8 bits, configurable odd, even or no parity Modbus serial
ATV6A0C80T6 — Mechanical
ParameterValue
Mounting modeCabinet mount
Terminal / wiring connectionControl removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars
Product destination / compatibilitySynchronous motors Asynchronous motors
ATV6A0C80T6 — Environmental
ParameterValue
Degree of protection (IEC, IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP rating (with kit options)IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Storage temperature-40...158 °F (-40...70 °C)
Operating altitude (with derating)< 2000 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Pollution degree2 IEC 61800-5-1
Environmental resistance classesChemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
Shock resistance4 gn 11 ms IEC 60068-2-27
Acoustic noise level73 dB 86/188/EEC
ATV6A0C80T6 — Approvals & Compliance
ParameterValue
StandardsIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1
Agency markings / approvalsCE

Product details

The Schneider ATV6A0C80T6 is a modular Altivar Process drive rated for 800 hp at 600 V normal duty, 650 hp heavy duty, with Safe Torque Off SIL 3 that meets IEC 61508. The integrated C3 EMC filter handles motor cable runs up to 300 m without an external filter — a real money saver in retrofits. It shrugs off the vibration (0.5 gn at 13–200 Hz) and shock (4 gn, 11 ms), so it survives the crusher floor. Line current: 670 A normal duty, 547 A heavy duty at 600 V. THDI stays below 48% at full load per IEC 61000-3-12. Apparent power 696 kVA normal, 568 kVA heavy.

Integration & wiring notes

Cabinet mount with forced convection cooling. Line side uses M10 x 2 bars; control wiring fits removable screw terminals 0.5–1.5 mm². Pollution degree 2 per IEC 61800-5-1. Switching frequency adjustable 2–4.9 kHz with derating, and operating altitude up to 2000 m with derating above 1000 m. Communication slot A fieldbus options include Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen. Modbus serial on 2-wire RS-485 at 4.8–38.4 kbps, RTU format, addresses 1–247. Ethernet at 10/100 Mbit/s with auto-negotiation.

Standard set includes a power module, control unit, mechanical mounting kits, power connection set of fuses, and front cover. The kit composition is ready for panel integration.

Frequently asked questions

What is the marking and variant for this drive?

The marking is CE, and the variant is the Modular version (power module plus control unit).

What compliance documentation is available for the ATV6A0C80T6?

The drive complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 61800-5-1. CE marking applies.

What are the key ratings for the ATV6A0C80T6?

Motor power: 800 hp normal duty, 650 hp heavy duty at 600 V. Line current: 670 A normal, 547 A heavy. Integrates a C3 EMC filter for 300 m cable runs. Safe Torque Off SIL 3. Shock 4 gn, vibration 0.5 gn.