Schneider Electric ATV6B0C11T4
MPNATV6B0C11T4
Active
variable speed drive APM, ATV600, Low Harmonic drive, 480 V, 150 hp
StockContact for availability
MOQ1 pcs
Sourced new & surplus through independent channelsListing updated Jun 2026
Specifications
Identification
| Parameter | Value |
|---|---|
| Product type | Variable speed drive |
| Device short name | ATV6B0 |
| Product range / family | Altivar Process ATV600 |
Power & Output
| Parameter | Value |
|---|---|
| Motor power (kW) | 110.0 kW at 480 V normal duty 90.0 kW at 480 V heavy duty |
| Continuous output current | 211.0 A at 2.5 kHz normal duty 173.0 A at 2.5 kHz heavy duty |
| Max. transient current | 232.1 A 60 s normal duty) 259.5 A 60 s heavy duty) |
| Apparent power | 123 kVA at 480 V normal duty 104 kVA at 480 V heavy duty |
Input / Supply
| Parameter | Value |
|---|---|
| Rated supply voltage range | 480 V - 10...10 % |
| Input line current | 148.0 A 480 V normal duty) 125.0 A 480 V heavy duty) |
| Network number of phases | 3 phases |
Control & Performance
| Parameter | Value |
|---|---|
| Output frequency range | 0...500 Hz |
| Asynchronous motor control modes | Constant torque standard Variable torque standard Optimized torque mode |
| Synchronous motor control modes | Permanent magnet motor Synchronous reluctance motor |
Protection & EMC
| Parameter | Value |
|---|---|
| Integrated EMC filter class | Integrated 984.3 ft (300 m) IEC 61800-3 category C3 |
| Protection functions | Thermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive |
| EMC immunity tests | Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6 |
| Prospective short-circuit current (Isc) | 50 kA |
Mechanical & Cooling
| Parameter | Value |
|---|---|
| Degree of protection (IP) | UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration) |
| IP degree of protection | IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529 |
| Acoustic noise level | 70 dB 86/188/EEC |
| Cooling method | Forced convection |
Environmental
| Parameter | Value |
|---|---|
| Operating ambient temperature | 14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor |
| Operating altitude | 1000...4800 m with current derating above 1000m |
| Relative humidity | 5...95 % without condensation IEC 60068-2-3 |
| Storage / transport temperature | -40...158 °F (-40...70 °C) |
| Pollution degree | 2 IEC 61800-5-1 |
| Vibration resistance | 1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6 |
Approvals
| Parameter | Value |
|---|---|
| Certifications & marking | CE |
| Standards compliance | IEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 |
Communication
| Parameter | Value |
|---|---|
| Communication protocols | Ethernet Modbus serial Modbus TCP |
MPN
ATV6B0C11T4