Specifications

ATV6B0C11T6 — Identification
ParameterValue
Product range / seriesAltivar Process ATV600
Device short name / model codeATV6B0
Product / component typeVariable speed drive
ATV6B0C11T6 — Electrical (input)
ParameterValue
Rated supply voltage600 V - 10...10 %
Network phases3 phases
Supply frequency50...60 Hz - 5...5 %
Line (input) current102.0 A 600 V normal duty) 82.0 A 600 V heavy duty)
Prospective line short-circuit current (Isc)50 kA
EMC filterIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Max. input current THD (THDi)<5 % full load IEEE 519
ATV6B0C11T6 — Output / Performance
ParameterValue
Apparent power106 kVA at 600 V normal duty 86 kVA at 600 V heavy duty
Continuous output current125.0 A at 2.5 kHz normal duty 105.0 A at 2.5 kHz heavy duty
Switching (PWM) frequency2...4.9 kHz adjustable with derating factor
ATV6B0C11T6 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP
Address range1...247 Modbus serial
Data format8 bits, configurable odd, even or no parity Modbus serial
ATV6B0C11T6 — Mechanical
ParameterValue
Mounting modeCabinet mount
Terminal / wiring connectionControl removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars
Product destination / compatibilitySynchronous motors Asynchronous motors
ATV6B0C11T6 — Environmental
ParameterValue
Degree of protection (IEC, IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP rating (with kit options)IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Storage temperature-40...158 °F (-40...70 °C)
Operating altitude (with derating)< 2000 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Pollution degree2 IEC 61800-5-1
Environmental resistance classesChemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
Shock resistance4 gn 11 ms IEC 60068-2-27
Acoustic noise level70 dB 86/188/EEC
ATV6B0C11T6 — Approvals & Compliance
ParameterValue
StandardsIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1
Agency markings / approvalsCE

Product details

Drive selection memo — ATV6B0C11T6

This Altivar Process ATV600 drive is sized for a 125 hp induction motor at 600 V normal duty, pulling 102 A line current. Under heavy duty it still delivers 100 hp with 82 A, so it holds up to the steam of a tire curing press where the load profile may demand a safety margin on current. Built as a modular version, it accepts slot A and B option cards for Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, or CANopen — the communication layer you need to nail the cure recipe across the line. The integrated EMC filter provides C3 category suppression per IEC 61800-3 for 300 m cable runs; standard compliance includes IEC 61800-5-1, UL 61800-5-1, and functional safety STO SIL3 per IEC 61508. Forced convection cooling and a 5–95% humidity range without condensation make it rated for press temperatures and steam-laden plant air — just keep the cabinet vent clear.

Cabinet integration checklist

Mounting: cabinet mount, UL Type 1 or Type 12 (conforming to UL 61800-5-1). Forced convection requires minimum clearances around the module — refer to the mechanical dimensions from the mounting kit. Electrical connection: line side via screw terminals; motor side via M10 x 2 bars. Control wiring: removable screw terminals accepting 0.5–1.5 mm² / AWG 20–16. Option cards plug into slots A and B; slot A also accepts communication modules, slot A/slot B accept I/O or relay extension. Communication: Modbus serial via 2-wire RS485 at 4.8–38.4 kbit/s RTU, plus Ethernet IP/Modbus TCP at 10/100 Mbit/s autonegotiation. Adjustable switching frequency from 2 to 4.9 kHz; derate above 1000 m altitude.

Frequently asked questions

What compliance documentation does this drive provide?

It is CE marked and complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 61800-5-1. Functional safety includes STO SIL3. RoHS/REACH declarations are available from Schneider on request.

What are the key electrical ratings?

Normal duty: 125 hp at 600 V, 102 A line current, 106 kVA apparent power. Heavy duty: 100 hp at 600 V, 82 A line current, 86 kVA. Output voltage equals supply voltage. The drive can handle synchronous and asynchronous motors.

What fieldbus options are available?

Slot A accepts Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen modules. Slots A or B accept digital/analog I/O extension or output relay extension. Built-in Modbus serial (RS485) and Ethernet IP/Modbus TCP are standard.

MPN
ATV6B0C11T6