Skip to main content
Schneider Electric ATV6B0C13T4 — AC Drive (VFD) 480V

Schneider ATV6B0C13T4 Altivar Process, 200 hp VFD

MPNATV6B0C13T4
Active

Schneider Electric Altivar Process ATV600 series, drive ATV6B0C13T4, modular version, 200 hp at 480 V normal duty, integrated EMC filter category C3, STO SIL3 safety.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV6B0C13T4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6B0
Product range / familyAltivar Process ATV600
ATV6B0C13T4 — Power & Output
ParameterValue
Motor power (kW)132.0 kW at 480 V normal duty 110.0 kW at 480 V heavy duty
Continuous output current250.0 A at 2.5 kHz normal duty 211.0 A at 2.5 kHz heavy duty
Max. transient current275 A 60 s normal duty) 316.5 A 60 s heavy duty)
Apparent power164 kVA at 480 V normal duty 123 kVA at 480 V heavy duty
ATV6B0C13T4 — Input / Supply
ParameterValue
Rated supply voltage range480 V - 10...10 %
Input line current197.0 A 480 V normal duty) 148.0 A 480 V heavy duty)
Network number of phases3 phases
ATV6B0C13T4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor Synchronous reluctance motor
ATV6B0C13T4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA
ATV6B0C13T4 — Mechanical & Cooling
ParameterValue
Degree of protection (IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Acoustic noise level70 dB 86/188/EEC
Cooling methodForced convection
ATV6B0C13T4 — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Operating altitude1000...4800 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
ATV6B0C13T4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1
ATV6B0C13T4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

Drive specs for the BOM line

The Schneider ATV6B0C13T4 is an Altivar Process ATV600 variable speed drive for asynchronous and synchronous motors. Rated 200 hp (132 kW) at 480 V normal duty and 150 hp (110 kW) heavy duty, with a 2.5–8 kHz adjustable switching frequency. The integrated EMC filter meets IEC 61800-3 category C3, so 300 m shielded cable runs are within spec without an external filter.

Integration and communication flexibility

Two expansion slots (A and B) accept fieldbus modules: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen, plus digital/analog I/O or output relay extensions. Onboard Modbus serial RTU (RS-485, 4.8–38.4 kbps) and Modbus TCP (10/100 Mbit/s) are standard. The supply voltage and line current — 197 A normal duty, 148 A heavy duty at 480 V — define the branch circuit sizing and the prospective 50 kA short-circuit current rating.

Frequently asked questions

What is the marking and variant on this drive?

It carries CE marking and is a modular version, meaning it comes as a kit with separate power module, control unit, and mounting parts.

What compliance documentation does this drive meet?

It complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The integrated EMC filter is category C3 per IEC 61800-3.

MPN
ATV6B0C13T4