Skip to main content
Schneider Electric ATV6B0C16N6 — AC Drives (VFD)

Schneider ATV6B0C16N6 Altivar Process ATV600, 110 kW

MPNATV6B0C16N6
Active

Schneider Electric Altivar Process ATV600, ATV6B0C16N6, modular drive, 110 kW at 500 V normal duty, line current 141 A, integrated EMC filter C3.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV6B0C16N6 — Identification
ParameterValue
Product rangeAltivar Process ATV600
Product / component typeVariable speed drive
ATV6B0C16N6 — Power & Current
ParameterValue
Continuous output current175.0 A at 2.5 kHz normal duty 145.0 A at 2.5 kHz heavy duty
ATV6B0C16N6 — Control & Communication
ParameterValue
Switching frequency2.5 kHz
Synchronous motor control profilePermanent magnet motor Synchronous reluctance motor
Communication protocols / portsEthernet Modbus serial Modbus TCP
Acceleration / deceleration rampsS, U or customized Linear adjustable separately from 0.01...9999 s
Product destinationSynchronous motors Asynchronous motors
ATV6B0C16N6 — Protection & Environmental
ParameterValue
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
Degree of protection (IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
ATV6B0C16N6 — Electrical
ParameterValue
Supply frequency50...60 Hz - 5...5 %
Network number of phases3 phases

Product details

Drive overview

The Schneider ATV6B0C16N6 is a modular Altivar Process ATV600 drive rated for 110 kW at 500 V normal duty, drawing 141 A line current at that condition. It handles both asynchronous and synchronous motors, with an adjustable switching frequency from 2 to 4.9 kHz. The integrated EMC filter meets category C3 per IEC 61800-3, good for up to 300 m of motor cable in typical industrial installations. The heavy-duty rating is 90 kW at 500 V with 117 A line current, so it carries the usual headroom for constant-torque loads or higher ambient conditions.

Integration and communication

The drive comes with a slot A for fieldbus option cards: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, and CANopen (RJ45 or SUB-D 9 or screw terminals). The base unit includes Modbus serial (2-wire RS485, RTU, up to 38.4 kbit/s) and Modbus TCP (10/100 Mbit/s) as standard. That covers most line-side connections without an extra card. For I/O expansion, slot A or slot B accepts digital/analog I/O extension modules or relay output modules. Cabinet mount, forced convection cooling. Pollution degree 2. Vibration resistance per IEC 60068-2-6: 1.5 mm peak-to-peak from 2 to 13 Hz, 0.5 gn from 13 to 200 Hz.

Safety and compliance

Safe torque off (STO) built in, rated SIL 3. Thermal protection for both motor and drive, plus short-circuit, earth fault, overvoltage/undervoltage, phase loss, and overspeed protection. Marking CE; design meets IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. Integrated EMC filter C3 keeps conducted emissions within limits for industrial second environment (not residential). No external filter needed for most installations.

Frequently asked questions

What compliance documentation comes with this drive?

The drive carries CE marking and is designed to IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The integrated EMC filter meets C3. Documentation supporting those standards is available on request.

What are the key electrical ratings?

Motor power: 110 kW normal duty / 90 kW heavy duty at 500 V. Line current: 141 A normal duty / 117 A heavy duty at 500 V. Apparent power: 122 kVA normal duty / 101 kVA heavy duty. Output voltage equals supply voltage. Line supply frequency 50/60 Hz ±5%.

MPN