Skip to main content
Schneider Electric ATV6B0C16T6 — AC Drive (VFD) 600V

Schneider Electric ATV6B0C16T6 Altivar Process ATV600, 175 h

MPNATV6B0C16T6
Active

Schneider Electric ATV6B0C16T6, Altivar Process ATV600 modular drive, 175 hp normal duty / 150 hp heavy duty at 600 V, integrated EMC filter C3, Safe Torque Off SIL3, current production.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6B0C16T6 — Identification
ParameterValue
Product range / seriesAltivar Process ATV600
Device short name / model codeATV6B0
Product / component typeVariable speed drive

Electrical (input)

ATV6B0C16T6 — Electrical (input)
ParameterValue
Rated supply voltage600 V - 10...10 %
Network phases3 phases
Supply frequency50...60 Hz - 5...5 %
Line (input) current142.0 A 600 V normal duty) 121.0 A 600 V heavy duty)
Prospective line short-circuit current (Isc)50 kA
EMC filterIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Max. input current THD (THDi)<5 % full load IEEE 519

Output / Performance

ATV6B0C16T6 — Output / Performance
ParameterValue
Apparent power147 kVA at 600 V normal duty 126 kVA at 600 V heavy duty
Continuous output current175.0 A at 2.5 kHz normal duty 145.0 A at 2.5 kHz heavy duty
Switching (PWM) frequency2...4.9 kHz adjustable with derating factor

Communication

ATV6B0C16T6 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP
Address range1...247 Modbus serial
Data format8 bits, configurable odd, even or no parity Modbus serial

Mechanical

ATV6B0C16T6 — Mechanical
ParameterValue
Mounting modeCabinet mount
Terminal / wiring connectionControl removable screw terminals 0.5...1.5 mm² AWG 20...AWG 16 Line side screw terminal Motor M10 x 2 bars
Product destination / compatibilitySynchronous motors Asynchronous motors

Environmental

ATV6B0C16T6 — Environmental
ParameterValue
Degree of protection (IEC, IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP rating (with kit options)IP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Storage temperature-40...158 °F (-40...70 °C)
Operating altitude (with derating)< 2000 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Pollution degree2 IEC 61800-5-1
Environmental resistance classesChemical pollution resistance class 3C3 IEC 60721-3-3 Dust pollution resistance class 3S3 IEC 60721-3-3 Humidity resistant class 3K3 IEC 60721-3-3
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6
Shock resistance4 gn 11 ms IEC 60068-2-27
Acoustic noise level70 dB 86/188/EEC

Approvals & Compliance

ATV6B0C16T6 — Approvals & Compliance
ParameterValue
StandardsIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1 UL 61800-5-1
Agency markings / approvalsCE

Product details

Drive core with fieldbus flexibility

The ATV6B0C16T6 is the main power-and-control assembly of the ATV600 line in a modular format. It delivers 175 hp at 600 V normal duty or 150 hp heavy duty, with a line current of 142 A normal / 121 A heavy. The drive is designed for asynchronous and synchronous motors. Slot A accepts any of the listed communication modules — Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen — so the network interface is chosen during integration, not baked in at order. The control unit and power module separate, making upgrades or field swaps simpler. Safety is covered on-board: Safe Torque Off (STO) to SIL 3 without an additional safety module. The integrated EMC filter (category C3) supports 300 m of motor cable, covering most industrial installations.

Production status and modular sourcing

The modular version means you can replace or upgrade the control unit or power module independently. If a later revision emerges mid-lifecycle, a full unit swap isn't forced — just the affected segment.

Cabinet installation and integration notes

Cabinet mount with forced convection cooling. Pollution degree 2 interior; UL type 1 or 12 as part of the cabinet integration. The kit includes one power module (200 kW), control unit, mechanical mounting kits, power connection set, and fuses — everything in one order code. For connection: line side screw terminal, motor M10 x 2 bars, control via removable screw terminals 0.5...1.5 mm². The switching frequency is adjustable from 2 to 4.9 kHz with derating. Default communication via Modbus serial (RS-485, 2-wire, RTU frame, up to 38.4 kbit/s) and Modbus TCP (10/100 Mbit/s, half/full duplex). The drive also carries multiple protections: thermal, short-circuit, overvoltage, undervoltage, phase loss, overspeed, and break on control circuit — all listed under protection type.

Frequently asked questions

What is ATV6B0C16T6's listed variant?

The variant is Modular version, meaning the control unit and power module are separate assemblies that can be sourced or replaced individually.

What is the CE marking on this drive?

The marking is CE as shown in the specifications.

What compliance documentation does Schneider provide for ATV6B0C16T6?

The drive complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, IEC 13849-1, and UL 61800-5-1.

MPN
ATV6B0C16T6