Schneider Electric ATV6B0C20T4 — AC Drive (VFD) 480V

Schneider ATV6B0C20T4 Altivar Process Drive, 200 kW, STO

MPNATV6B0C20T4
Active

Schneider Electric Altivar Process ATV600, modular version, 200 kW normal duty at 480 V, STO SIL3.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6B0C20T4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6B0
Product range / familyAltivar Process ATV600

Power & Output

ATV6B0C20T4 — Power & Output
ParameterValue
Motor power (kW)200.0 kW at 480 V normal duty 160.0 kW at 480 V heavy duty
Continuous output current370.0 A at 2.5 kHz normal duty 302.0 A at 2.5 kHz heavy duty
Max. transient current407 A 60 s normal duty) 453 A 60 s heavy duty)
Apparent power243 kVA at 480 V normal duty 203 kVA at 480 V heavy duty

Input / Supply

ATV6B0C20T4 — Input / Supply
ParameterValue
Rated supply voltage range480 V - 10...10 %
Input line current292.0 A 480 V normal duty) 245.0 A 480 V heavy duty)
Network number of phases3 phases

Control & Performance

ATV6B0C20T4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor Synchronous reluctance motor

Protection & EMC

ATV6B0C20T4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated 984.3 ft (300 m) IEC 61800-3 category C3
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA

Mechanical & Cooling

ATV6B0C20T4 — Mechanical & Cooling
ParameterValue
Degree of protection (IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
Acoustic noise level73 dB 86/188/EEC
Cooling methodForced convection

Environmental

ATV6B0C20T4 — Environmental
ParameterValue
Operating ambient temperature14...104 °F (-10...40 °C) without derating 104...122 °F (40...50 °C) with derating factor
Operating altitude1000...4800 m with current derating above 1000m
Relative humidity5...95 % without condensation IEC 60068-2-3
Storage / transport temperature-40...158 °F (-40...70 °C)
Pollution degree2 IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV6B0C20T4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV6B0C20T4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

The Schneider ATV6B0C20T4 is a current-production Altivar Process ATV600 drive in a modular cabinet-mount variant. It delivers 200 kW (300 hp) at 480 V under normal duty and 160 kW (250 hp) under heavy duty, drawing 292 A and 245 A line current respectively. The integrated EMC filter meets category C3 per IEC 61800-3, and the drive includes Safe Torque Off rated SIL 3.

Ratings that decide the install

The dual power rating governs both motor match and upstream protection. Heavy duty (160 kW) gives a 245 A line current for constant-torque loads like conveyors; normal duty (292 A) suits variable-torque fans and pumps. The switching frequency is adjustable 2.5–8 kHz, with derating above the factory default — something you'll want to set before commissioning if running high-speed spindle applications. The 50 kA prospective line Isc rating means this drive sits behind a breaker with at least that interrupting capacity. The 4 gn shock and 1.5 mm peak-to-peak vibration resistance are standard for industrial panel mounting — nothing exotic, but confirms you don't need extra isolation pads for typical floor vibration. Built-in Modbus serial and Ethernet ports handle 10/100 Mbit/s with auto-negotiation for Modbus TCP, plus the serial runs at selectable 4.8–38.4 kbit/s. Slot A accepts Profibus DP, PROFINET, DeviceNet, or CANopen option cards — that's where you route fieldbus integration without external gateways.

Compliance and standards scope

The drive carries CE marking and holds IEC 61800-3, 61800-5-1, 61000-3-12, 60721-3, 61508, and 13849-1 compliance. The STO function is SIL 3, meeting machine safety directive requirements. The integrated C3 EMC filter is sized for 300 m of cable, which covers the majority of industrial runs without an external filter. Pollution degree 2 suits normal factory environments — no chemical or conductive dust exposure needed.

Frequently asked questions

What is the ATV6B0C20T4's marking and variant?

It carries CE marking and is the modular version of the Altivar Process ATV600 range.

What compliance documentation does this drive meet?

It complies with IEC 61800-3, IEC 61800-5-1, IEC 61000-3-12, IEC 60721-3, IEC 61508, and IEC 13849-1. The STO function is SIL 3.