Skip to main content
Schneider Electric ATV6B0C31Q4 — AC Drive (VFD) 480V

Schneider ATV6B0C31Q4 Drive, 315 kW, 400 V, modular, CE

MPNATV6B0C31Q4
Active

Schneider Electric Altivar Process ATV600 modular drive, CE marked, 315 kW normal duty / 250 kW heavy duty at 400 V, integrated EMC filter, STO SIL3.

StockContact for availability
Lead timeIn Stock wk
MOQ1 pcs
Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Jul 2026
How we verify every order →

Specifications

Identification

ATV6B0C31Q4 — Identification
ParameterValue
Product typeVariable speed drive
Device short nameATV6B0
Product range / familyAltivar Process ATV600

Power & Output

ATV6B0C31Q4 — Power & Output
ParameterValue
Motor power (kW)315.0 kW at 400 V normal duty 250.0 kW at 400 V heavy duty
Continuous output current590.0 A at 2.5 kHz normal duty 477.0 A at 2.5 kHz heavy duty
Max. transient current649 A during 60 s (normal duty) 715.5 A during 60 s (heavy duty)
Apparent power340 kVA at 400 V normal duty 270 kVA at 400 V heavy duty

Input / Supply

ATV6B0C31Q4 — Input / Supply
ParameterValue
Rated supply voltage range400 V - 15...10 %
Input line current491.0 A at 400 V (normal duty) 389.0 A at 400 V (heavy duty)
Network number of phases3 phases

Control & Performance

ATV6B0C31Q4 — Control & Performance
ParameterValue
Output frequency range0...500 Hz
Asynchronous motor control modesConstant torque standard Variable torque standard Optimized torque mode
Synchronous motor control modesPermanent magnet motor Synchronous reluctance motor

Protection & EMC

ATV6B0C31Q4 — Protection & EMC
ParameterValue
Integrated EMC filter classIntegrated with 300 m conforming to IEC 61800-3 category C3
Protection functionsThermal protection: motor Safe torque off: motor Motor phase break: motor Thermal protection: drive Safe torque off: drive Overheating: drive Overcurrent between output phases and earth: drive Overload of output voltage: drive Short-circuit protection: drive Motor phase break: drive Overvoltages on the DC bus: drive Line supply overvoltage: drive Line supply undervoltage: drive Line supply phase loss: drive Overspeed: drive Break on the control circuit: drive
EMC immunity testsElectrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Prospective short-circuit current (Isc)50 kA

Mechanical & Cooling

ATV6B0C31Q4 — Mechanical & Cooling
ParameterValue
IP degree of protectionIP00 (for IP21 or IP54 cabinet integration) conforming to IEC 61800-5-1 IP00 (for IP21 or IP54 cabinet integration) conforming to IEC 60529
Acoustic noise level73 dB conforming to 86/188/EEC
Cooling methodForced convection

Environmental

ATV6B0C31Q4 — Environmental
ParameterValue
Operating ambient temperature-10...40 °C without derating 40...50 °C with derating factor
Operating altitude1000...4800 m with current derating above 1000m
Relative humidity5...95 % without condensation conforming to IEC 60068-2-3
Storage / transport temperature-40...70 °C
Pollution degree2 conforming to IEC 61800-5-1
Vibration resistance1.5 mm peak to peak (f= 2...13 Hz) conforming to IEC 60068-2-6 0.5 gn (f= 13...200 Hz) conforming to IEC 60068-2-6

Approvals

ATV6B0C31Q4 — Approvals
ParameterValue
Certifications & markingCE
Standards complianceIEC 61800-3 IEC 61800-5-1 IEC 61000-3-12 IEC 60721-3 IEC 61508 IEC 13849-1

Communication

ATV6B0C31Q4 — Communication
ParameterValue
Communication protocolsEthernet Modbus serial Modbus TCP

Product details

Kit contents and installation constraints

The ATV6B0C31Q4 is a modular Altivar Process ATV600 drive rated for 315 kW normal duty at 400 V (250 kW heavy duty). It ships as a complete kit: the power module (160 kW section), control unit, mechanical mounting kits, power connection set with fuses, and front cover — no separate accessories needed to get it on a cabinet floor. Integrated EMC filter is rated for 300 m shielded motor cable per IEC 61800-3 category C3. Longer runs demand an external filter. Forced convection cooling dissipates 13380 W at 2.5 kHz switching frequency in normal duty. Motor power connections use M10 bars on the line side; control wiring is removable screw terminals accepting 0.5–1.5 mm². The modular construction means you can replace the power module without pulling the full drive — handy for spares planning.

Compliance and safety functions

Pollution degree 2, vibration and shock resistance per IEC 60068, operating altitude up to 4800 m with derating above 1000 m. The drive handles both asynchronous and synchronous motors, adjustable switching frequency 2.5–8 kHz. Braking by DC injection, protection suite includes thermal, overcurrent, short-circuit, ground fault, phase loss, overspeed, and DC bus over/undervoltage. Maximum prospective line Isc is 50 kA.

For a BOM freeze, the ATV6B0C31Q4 is the complete kit. When you RFQ, we quote against your required lead time. The CE marking and IEC 61800-3, -5-1, -3-12, 60721-3, 61508, and 13849-1 compliance are documented; nameplate and PO traceability are standard.

Frequently asked questions

What compliance documentation does this drive have?

It carries CE marking and complies with IEC 61800-3 (EMC), IEC 61800-5-1 (safety), IEC 61000-3-12, IEC 60721-3 (environmental), IEC 61508 and IEC 13849-1 (functional safety). The integrated EMC filter meets category C3 with up to 300 m shielded cable.

What is the variant of this drive?

It is the modular version, meaning it ships as a kit of control unit, power module, mounting hardware, connection set, fuses, and front cover. This allows separate replacement of the power section for easier maintenance.

What is its marking?

The marking is CE, indicating conformity with applicable European directives.

MPN
ATV6B0C31Q4