Skip to main content
Schneider Electric ATV6B0C40N6 — AC Drives (VFD)

Schneider ATV6B0C40N6 280 kW 500 V Drive, STO SIL 3

MPNATV6B0C40N6
Active

Schneider Electric Altivar Process ATV600, modular drive, 280 kW at 500 V normal duty, 200 kW power module included, integrated EMC filter C3, STO SIL 3 safety.

Sourced new & surplus through independent channelsAuthenticity-screened · ESD-safe packingListing updated Aug 2026

Specifications

ATV6B0C40N6 — Identification
ParameterValue
Product rangeAltivar Process ATV600
Product / component typeVariable speed drive
ATV6B0C40N6 — Power & Current
ParameterValue
Continuous output current425.0 A at 2.5 kHz normal duty 340.0 A at 2.5 kHz heavy duty
ATV6B0C40N6 — Control & Communication
ParameterValue
Switching frequency2.5 kHz
Synchronous motor control profilePermanent magnet motor Synchronous reluctance motor
Communication protocols / portsEthernet Modbus serial Modbus TCP
Acceleration / deceleration rampsS, U or customized Linear adjustable separately from 0.01...9999 s
Product destinationSynchronous motors Asynchronous motors
ATV6B0C40N6 — Protection & Environmental
ParameterValue
Protection functionsThermal protection motor Safe torque off motor Motor phase break motor Thermal protection drive Safe torque off drive Overheating drive Overcurrent between output phases and earth drive Overload of output voltage drive Short-circuit protection drive Motor phase break drive Overvoltages on the DC bus drive Line supply overvoltage drive Line supply undervoltage drive Line supply phase loss drive Overspeed drive Break on the control circuit drive
Degree of protection (IP)UL type 1 conforming to UL 61800-5-1 (cabinet integration) UL type 12 conforming to UL 61800-5-1 (cabinet integration)
IP degree of protectionIP00 for IP21 or IP54 cabinet integration)IEC 61800-5-1 IP00 for IP21 or IP54 cabinet integration)IEC 60529
ATV6B0C40N6 — Electrical
ParameterValue
Supply frequency50...60 Hz - 5...5 %
Network number of phases3 phases

Product details

The ATV6B0C40N6 is a modular Altivar Process ATV600 drive rated for 280 kW at 500 V in normal duty and 220 kW in heavy duty, with line currents of 352 A (normal) and 278 A (heavy). It ships as a kit including the 200 kW power module, control unit, and mounting hardware.

Ratings & integration

Cabinet mount, forced convection cooling. Degree of protection UL type 1 or 12 when integrated into a cabinet. The integrated EMC filter meets IEC 61800-3 category C3 for 300 m cable runs — no external filter needed for most installations. Line-side connection via M10 bars; motor connection also M10 bars. Control wiring uses removable screw terminals, 0.5–1.5 mm² (AWG 20–16). Switching frequency adjustable 2–4.9 kHz with derating. Braking by DC injection.

Communication & safety

Slot A accepts fieldbus option cards: Profibus DP V1, PROFINET, DeviceNet, Modbus TCP/EtherNet/IP, CANopen (RJ45 or SUB-D 9 or screw terminals). Built-in Modbus serial RS-485 (2-wire, RTU, 4.8–38.4 kbps) and Modbus TCP Ethernet (10/100 Mbps, half/full duplex). Up to 247 Modbus serial addresses. Safe Torque Off (STO) certified SIL 3 per IEC 61508 / IEC 13849-1, eliminating external safety relays for the stop function. Thermal motor protection, motor phase break, and overcurrent protections included.

Frequently asked questions

What are the key power ratings?

Motor power 280 kW normal duty / 220 kW heavy duty at 500 V, with line currents 352 A normal / 278 A heavy duty.

Does this drive include an EMC filter?

Yes, an integrated EMC filter meets IEC 61800-3 category C3 for cable lengths up to 300 m.

What safety functions are built in?

Safe Torque Off (STO) rated SIL 3, plus thermal and phase-break protections for motor and drive.

What communication protocols are supported?

Built-in Modbus serial RS-485 and Modbus TCP Ethernet. Slot A accepts Profibus DP, PROFINET, DeviceNet, Modbus TCP/IP, and CANopen option cards.

MPN